Laserfiche WebLink
23. Tamper- Resistant Receptacles in accordance with 406.11 ofthe 2016 N.E.0 <br /> 24. In accordance with the Land Development Code, lots shall be sodded before final at least 10 <br /> feet around the structure. <br /> 25-. R403.5.3Hot.waier.'pipe insulation <br /> Insulation for hot water pipe with a minimum thermal resistance(R.value) of R-3 shall be applied to the- <br /> following: <br /> Piping -1, inch-(19:1 mm)and larger in nominal diameter._ <br /> Piping serving more than:one dwelling unit. <br /> Piping located outside'tie conditioned space: <br /> Piping from the water heater to a distribution manifold. <br /> Piping:located under a floor slab." <br /> Buried in piping. <br /> Supply and return piping in recirculation systems other than demand'recirculation systems. <br /> 25. Blower door test shall be provided before C.O. <br /> 26.A copy of the energy-cacls shall be=with-permit at all limes <br /> 27. CoPP of final insulation report shall be provided with Permit before fnaL <br /> 28.1 No fence,Pool or screen enclosure :is issued with ihis permit <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C-Florida Building Code 6t'Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric,Code (2016) <br />