Search
20-315
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-315
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2022 3:40:10 PM
Creation date
3/3/2022 3:40:09 PM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
20-315
Building Department - Name
BOLENDER,CHAD
Address
6101 17TH ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
.t <br /> re ' <br /> EXTERIOR RESEARCH&DESIGN, LLC. <br /> Certificate of Authorization#9503 <br /> .1 1 ERD 353 Christian Street <br /> Oxford,CT 06478 <br /> (203)262-9245 <br /> EVALUATION REPORT <br /> Mule-Hide Products Co., Inc. Evaluation Report M15060.06.09-R5 <br /> 1195 Prince Hall Drive;Suite A FL12772-R5 <br /> Beloit,WI 53511-5481 Date of Issuance:06/24/2009 <br /> (608)365-3111 Revision 5:09/11/2017 <br /> SCOPE: <br /> This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of <br /> construction materials in the Stbte of Florida.The documentation submitted has been reviewed by Robert Nieminen, <br /> P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for <br /> compliance with the 61h Edition(2017) Florida Building Code sections noted herein. <br /> DESCRIPTION:;:Mule=Hide�TPO=e'-,Single.Piy}:Ro_o,.f;Systems:r <br /> LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted <br /> herein. <br /> CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named prod uct(s).changes,the referenced <br /> Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of <br /> this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product <br /> changes or the referenced Quality Assurance documentation changes. Trinityl ERD requires a.complete review of this <br /> Evaluation Report relative to updated Code requirements with each Code Cycle. <br /> ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in <br /> advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. <br /> INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or <br /> its distributors and shall be available for inspection at the job site at the request of the Building Official. <br /> This Evaluation Report consists of pages 1 through 4, plus a 27-page Appendix. <br /> Prepared by: <br /> Robert J.M.Nieminen,P.E. : <br /> _ The facsimile seal appearing was authorized by Robert Nieminen, <br /> Florida Registration No.59166,Florida DCA ANE1983 P.E.on 09/11/2017.This does not serve as an electronically signed <br /> .1✓+r'�rau�'tq�sN document. <br /> CERTIFICATION OF INDEPENDENCE: <br /> 1. Exterior Research&Design,LLC,d/b/a Trinity I ERD does not have,nor does it intend to acquire or will it acquire,a financial interest <br /> in any company manufacturing or distributing products it evaluates. <br /> 2. Exterior Research & Design, LLC. d/b/a Trinity I ERD is not owned, operated or controlled by any company manufacturing or <br /> distributing products it evaluates. <br /> 3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for <br /> which the evaluation reports are being issued: <br /> 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial Interest in any other entity involved in the approval process of the <br /> product. <br /> 5. This is a building code evaluation. Neither TrinitvIERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any <br /> project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained <br /> specifically for that purpose. <br /> JUN <br /> ALL WORK SHAi L COI�PftY WITH PREVAILING REVIEw oATE <br /> CODES FLORID.A SULDING CODE, CITY OF ZEPHYRF�' <br /> NATIONAL ELECTRIC CODE, F'L�4N ENBiNER <br /> AND THE CITY OF ZEPHYRHILLS <br /> ORDINANCES <br />