Laserfiche WebLink
23. Tamper-Resistant Receptacles in accordance with 406.11 of the 2016 N.E.C' <br /> .24: In accordance with the Land Development Code,lots shall be sodded before final at.least 10. <br /> feet around the structure. <br /> 25: R403.5,3Hot water pipe insulation <br /> insulation for hot.water'pipe with'a minimum thermal resistance(R-value) of R-3 shall.be applied to the <br /> following: . <br /> Piping 3h inch (1.9.1 mm)and larger in:nominal diameter. <br /> Piping.serving more than one dwelling unit. <br /> Piping located outside the conditioned space.. <br /> Piping from the water heater to a distribution manifold, <br /> Piping.located under a floor slab. <br /> Buried in piping, <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25: Blower door'test shall be provided before C.O: <br /> 26.A copy ofthe eneryy cacls shall be with permit at all times. <br /> 27. Copy of final insulation report shall be provided with Permit before final <br /> 28. No fence,pool or screen enclosure .is issued with this permit <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C--Florida Building Code 6th Edition <br /> R.O.W.-Right of Way <br /> A.D.A.=Americans with.Disabilities Act N.E.C.-National Electric Code (2016) <br />