Laserfiche WebLink
23. Tamper- Resistant Receptacles in accordance with 406:11 of the 2016 N.E.0 <br /> 24. In accordance with the Land Development Code,lots shall.be sodded before final at least 10 <br /> feet around the structure. <br /> 25. R403.5.3Hot water'pipe insulation, <br /> Insulation for hot water'pipe with a minimum thermal resistance (R-value) of R-3.shall be'applied to the <br /> following: <br /> Piping./: inch (19.1 mm)and larger in:nominal.diameter. <br /> Piping.serving more than:one dwelling unit. <br /> Piping located outside the conditioned space: <br /> Piping from the water heater to a distribution manifold: <br /> Piping located under a floor slab. <br /> Buried in piping. <br /> Supply and return piping in recirculation-systems other than demand recirculation systems. <br /> 25: Blower door test shall be provided before C.O: <br /> .26. A copy of the eng=eacls shall be ivith permit at all times. <br /> 27 Copy of final insulation reoort shall be provided with permit before fnab <br /> 28. No feike, pool or screen enclosure :is issued with:this permit <br /> F.F.E.-Finished FloorEle'vation .- <br /> F.B.C-Florida Building Code 6t'Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2016) <br />