Laserfiche WebLink
D <br /> Q, <br /> Single Family Dwelling <br /> Plan Review Comments <br /> J. F.F.E..shall.be a minimum of 8" above the road elevation and an engineered site plan. <br /> 2. Lots shall be graded to.comply with R401:3 of the F.-B.C. <br /> 3: Compaction test required if 24"or more of fill.dirt is brought in at any one place. <br /> 4: Tie in survey required before pouring concrete. <br /> 5-. .Driveways require.a R.O:W. use permit. All 4 sides of drivewaythru the sidewalk shall have- <br /> expansion material. <br /> 6. All setbacks shall be met. <br /> 7: All property markers s1ia11 be uncovered and marked at time:of fir st'inspection. <br /> 8: All A.D.A.requirements §Ball be met: <br /> 9-. No electric,.plumbing;mechanical,or framing shall be:covered without an inspection and <br /> approval first. <br /> 10.. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation).: <br /> . . <br /> 11. Appliances shall notbe installed in a-location where subject to_mechanical damage unless <br /> protected by approved barriers. M303:4 of the FAC <br /> 12. Water heaters shall comply with section 1?607.3 of the F.B.C: <br /> 13.Foundation supports for A/C units shall.be-raised at least 3" above finished grade. M1308.1 <br /> . 14..Return air in all bedrooms. F.B.C. M1620.4 <br /> 15. Smoke-detectors are to be installed in accordance with.R313.1 of the F.B.C. <br /> 16:All glazing requirements are to be iri accordance with R308A of the F.B.C: <br /> 17. All means of egress are to:be'in accordance with R311 of the F.B.C. <br /> 18.-`-`Green-gypsum board" shall not be used as a backer in showers or tubs.R702.4.2 F.B.C. <br /> 19. Combination type AFCI breakers are.required at all.locations requiring an AFCI type breaker. <br /> 20. Carbon monokide alarms will be required in new constrdction that uses fossil-burning heating-. . <br /> or appliances or an attached garage. They shall.be installed in accordance with the F.B.C: <br /> 2.1. All plumbing,inechanical, and electrical shall be separate from unit to unit: This includes all <br /> underground plumbing and electric. <br /> 22. All 2016 ME.C. Codes will be enforced. <br />