Laserfiche WebLink
MIN.EMBEDMENT SUBSTRATE' <br /> �® <br /> SEE TABLE 1 MOTHERS <br /> TYPICAL HEAD ANCHORAGE 1/4'MAX SHIM MIN.EDGE DIST. SUBSTRATE SEE TABLE 1 WINDOW SYSYEMS <br /> MIN.EDGE DIST. 1900 SW 44TH AVE. <br /> SEE TABLE 1 SEE TABLE 1 BY OTHERS <br /> 1/4"MAX SHIM SEE TABLE 1 OCALA FLORIDA 3474 <br /> WWW.CWS.CC <br /> SUBSTRATE BY OTHERS MIN.EDGE DIST. <br /> SEE TABLE 1 o SEE TABLE 1 <br /> MIN.EMBEDMENT INSTALLATION ANCHOR GZO PVC <br /> PERIMETER SEALANT SEE TABLE 1 SEE TABLE 1 <br /> BYINSTALLR HORIZ.SLIDER <br /> INSIDE AND OUT IN.EMBEDMENT <br /> SEALANT BEHIND (=] SEE TABLE 1 NON-IMPACT <br /> FLANGE BY INSTALLER 1/4"MAX SHIM 010000 TZ <br /> Qo PERIMETER SEALANT F <br /> BYINSTALLER Q <br /> BYINSPERIMTALL R��� INSIDEANDOUT <br /> INSIDE AND OUT INSTALLATION ANCHOR } <br /> SEALANT BEHIND JL014, <br /> SEE TABLE i m <br /> FLANGE BY INSTALLER SEALANT BEHIND CID <br /> INSTALLATION ANCHOR FIN BY INSTALLER ZO <br /> SEE TABLE 1 HORIZONTAL SECTION C HORIZONTAL SECTION <br /> 6 TYPICAL FIN ANCHORAGE N <br /> TYPICAL JAMB ANCHORAGE 6 HEAD AND SILL SIMILAR FOR FIN INSTALLATION ZO W <br /> 0 <br /> NOTE:ADDITIONAL THRU-FRAME ANCHORS a <br /> (AS SHOWN IN DET.A/6)REQ'D AT MTG RAIL, <br /> SEE SHEET 5 ANCHOR LAYOUT. w <br /> 0 <br /> CI <br /> I II <br /> Z <br /> SEALANT BEHIND 1/4'MAX SHIM ��i�p� <br /> FLANGE BY INSTALLER P��PS,ND..N S ;t <br /> PERIMETER SEALANT MIN.EMBEDMENT %41 <br /> JV; v `c•'•�1n% <br /> BY INSTALLER SEE TABLE 1 ti. : No 5B201 '�75 <br /> INSIDE AND OUT <br /> SUBSTRATE BY OTHERS MIN.EDGE DIST. STATE OF :'4+:0: <br /> SEE TABLE 1 SEE TABLE i <br /> SEALANT UNDER SCREW VERTICAL SECTION yA�SF�0 R t O P �Z <br /> � <br /> HEAD BY INSTALLER 6 TYPICAL SILL ANCHORAGE �Ziy/ONA„ ���` <br /> z� <br /> 4/27/2015 <br /> TABLE 1:APPROVED INSTALLATION FASTENERS LUCAS A.TURNER,P.E. <br /> FRAME TYPE SUBSTRATE TYPE ANCHOR TYPE MIN.EMBEDMENT MIN.EDGE DIST. FL PE#58201 <br /> FLANGE CONCRETE(2.0 KSI MIN.) 3/16"ITW TAPCON 1" 1-1/8" PERIMETER SEALANT 1239 JABARA AVE. <br /> FLANGE HOLLOW OR GROUP FILLED CMU(117 PCF MIN.) 3/16"ITW TAPCON 1" 2" BY INSTALLER NORTH PORT,FL 34288 <br /> FLANGE CONCRETE(2.85 KSI MIN.) 3/16"ELCO ULTRACON 1" 1" INSIDE AND OUT PH.941-380-1574 <br /> D HORIZON TAL SECTION <br /> FLANGE HOLLOW or GROUT-FILLED CMU(ASTM C-90) 3/16"ELCO ULTRACON 1-1/4' 2-112" 8 BOX FRAME INSTALLATION SHEET EscRIPrION: <br /> 3116'ITW TAPCON SIMILAR FOR SILL AND JAMBS FOR BOX INSTALLATION <br /> FLANGE 2XMIN SOUTHERN PINE(G=0.55) OR ELCO ULTRACON 1-3/8° 7/8" INSTALLATION DETAILS <br /> FLANGE 2XMIN.SOUTHERN PINE(G=0.55) #10 WOOD SCREW 1-318" 7/8" FLANGE REMOVAL NOTE:PARTIALLY OR FULLY REMOVING THE FLANGE, DRAWN BY: DATE: <br /> 16 GAUGE(0.060°)MIN.STEEL STUD #10.16 HILTI KWIK-FLEXOR ITW FULL THREAD UP TO AND INCLUDING A BOX-FRAME APPLICATION IS ACCEPTABLE PROVIDED: EMK 04/22/15 <br /> FLANGE (33 KSI YIELD M" TEKS SELF-DRILLING SCREW THRU 0.060" 7/16" MIN.1/4"FILLET OF CONSTRUCTION-GRADE ADHESIVE CAULK IS APPLIED D x: <br /> 1/8"ALUM.(6063-T5 MIN.)OR #10 GRADE 5 SELF-TAPPING/ FULL THREAD INSIDE AND OUT,FULL PERIMETER,BY INSTALLER. <br /> FLANGE 7/16° CWS 1059 - <br /> 1!8"STEEL(33 KSI MIN.) DRILLING SCREW THRU 0.125" -PRODUCT ANCHORAGE IS IN ACCORDANCE WITH REQUIREMENTS AS <br /> FIN 2XMIN.SOUTHERN PINE(G-0.55) #10 WOOD SCREW 1-1/2" 1/2" SHOWN FOR FLANGE WINDOWS. scALE .SHEET <br /> 1:2 60F6 <br /> J <br />