My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-353
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-353
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2022 4:04:23 PM
Creation date
3/3/2022 4:04:22 PM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
20-353
Building Department - Name
FROST,BARBARA & DONALD
Address
5533 9TH ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
® . . . : ' G61iC'Woas'\t <br /> SUPPLY & MANUFACTURING <br /> . ■ , � ■ ■ • , � ■ ■ • • 1 PSI•!. � � �..' � ..�.' h� <br /> Tlvl <br /> ENGINEER LOAD TABLE: 26 Ga. GulfRibTM Panel over 15/32"Plywood <br /> Buildings,having a Roof Mean'He'ight<-.20'-O"; Roof Slope: 2"%1'2" - 12"/92" Gable or Hip Roof;Wind:Speeds 1207 <br /> 180mph, Exposure:C, Risk Cato- II, Enclosed Buildino',based on Florida Building Cod le.2017: <br /> 120 130 140 150 160 170 180 <br /> WIIND FASTENER SUBSTRATE <br /> SPEED (MIN- (MIN.15/32") ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER <br /> Penetration) SPACING SPACING SPACING SPACING SPACING SPACING SPACING <br /> ZONE 1 , #9-15x1.5" Plywood 24",TYPE 1 24",TYPE 1 24",-TYPE 1 '24";TYPE 1 24 TYPE 1 24",TYPE 1 24",,TYPE T <br /> ZONE 2 #9-15x1.5" Plywood 24",TYPE 1 24",TYPE 1 24",TYPE 1 24",TYPE 1 24",TYPE 1 24",TYPE 1 24",TYPE 2 <br /> ZONE 3 #9-15x1.5" Plywood ' 24",TYPE 1 24",TYPE 1 24",:TYPE 1 12",TYPE 2 12",TYPE 2 '12",TYPE 2 '12",TYPE 2 <br /> 1.)PANEL DESCRIPTION:GULFRIBTM' MIN.26 GA., GRADE 80,36"COVERAGE,3/4" TALL. <br /> 2.)PANEL FASTENER:#9-15X1.5" HWH WITH SEALING WASHER OR APPROVED EQUAL <br /> 3.)MAXIMUM ALLOWABLE PANEL UPLIFT PRESSURE:69.25 PSF @ 24" O.C. FASTENER SPACING TYPE I FASTENER PATTERN, 159.25 <br /> PSF @ 12" O.C. FASTENER SPACING TYPE 2 FASTENER PATTERN BASED ON TAS 125, UL 580/UL 1897 TESTING. <br /> 4.)PLYWOOD DECKING: MIN.15/32"THICK PLYWOOD MUST BE DESIGNED IN ACCORDANCE WITH FLORIDA BUILDING CODE 2017. <br /> 5.)ROOF SLOPE:ON ROOF SLOPES LESS THAN 3:12, LAP SEALANT MUST BE USED IN PANEL SIDE LAPS. <br /> 6.)LOAD TABLE BASED ON WIND PRESSURES CALCULATED PER ASCE 7-10(KD=0.85)MULTIPLIED BY 0.6 PER FLORIDA BUILDING <br /> CODE 2017. <br /> ZONE2 HIP ROOF Note:Dimension(a)is defined as 10%of the minimum width of the building or <br /> ZONE 3 T I 40%of the mean height of the roof,whichever is smaller,however,(a)cannot be <br /> -----------------> --J a less than either 4%of the minimum width of the building or 3 feet <br /> � TYPE 1 FASTENER PATTERN RIDGE �i � 9.1 9° 91, <br /> \ \-- ------� I � IAtP.n.l Lap <br /> I <br /> ZONE 1 \\ \\\ L Cont.Tape Seal for use on Slopes less than 3:12 <br /> \ \ (1)#9-15 x 1-1/2'w/Sealer Washer @ 24'O.C.Max. <br /> SAVE <br /> -ZONE 2 65TYPE 2 FASTENER PATTERN <br /> GABLE ROOF 65" 25°{— . .—{ .5F .5"7 <br /> 2.5"T-6.5' 2.5° <br /> - ----------------- — . <br /> i <br /> I I <br /> I I <br /> RIDGE L Cont.Tape Seal for use on Slopes less than 3:12 <br /> (1)#9-15 x 1-1/2'w/Sealer Washer @ 12'O.C.Max. <br /> -----------------------� — a <br /> ZONE 1 <br /> I I <br /> +--\--------------------- <br /> "-ZONE3 \-EAVE <br /> FL#11651.22 R3•OCTOBER S,2017 <br /> ENGINEERING,KUHN <br />
The URL can be used to link to this page
Your browser does not support the video tag.