Laserfiche WebLink
GENERAC® <br /> 16/20/22 kW switch options <br /> Limited Circuits Switch Features Model 6007036-1(160) _ <br /> • 16 space,24 circuit,breakers not included. No <br /> _ <br /> • Electrically-operated,mechanically-held contacts for fast,positive Current Rating(Amps) 100 <br /> connections <br /> Volage Rabng(VAC) � .:: 120/240 i9 ; <br /> utility Voltage Monitor(Foxed)* <br /> • Rated for all classes of load,100%equipment rated,both inductive and -rick-up eon <br /> resistive. -Dropout _ _ _ 65% _ <br /> • 2-pole,250 VAC Contactors. }Return to Utility'_ Japprox 15"sec; , <br /> • 30 millisecond transfer time. Exercises bi-weekly for 5 minules•t w Standard <br /> • Dual coil design. <br /> • Rated for both copper and aluminum conductors. Total circuits Available 24- <br /> • Main contacts are silver plated or silver alloy to resist welding and sticking. Tandem ereakercapahiiines', T .::atanndems <br /> • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor Circuit Breaker Protected <br /> Available RMS symmetrical 10,000 <br /> mounting flexibility. Fault current @ 250 Volts <br /> • Multi listed for use with 1"standard,tandem,GFCI and AFCI breakers from *Function of Evolution Controller <br /> Siemens,Murray,Eaton and Square D for the most flexible and cost effec- Exercise can be set to weekly or monthly <br /> tive install. <br /> Dimensions "' <br /> Height Width Depth <br /> H1 I H2 w1 W2 <br /> in 26.75 30.1 10.5 13.5 6.91 <br /> mm 679.4 764.3 266.7 343.0 175.4 <br /> Wire Ranges =.a <br /> Conductor Lug Neutral Lug Ground Lug DE am l—wZ—I <br /> 119-#14 2l0-#14 210-#14 <br /> Service Rated Smart Switch Features Model G007037-1(16 kW)/GO07039-1(20 kw)/ <br /> • Includes Digital Power Management Technology standard(DPM). <br /> • Intelligently manages up to four air conditioner loads with no additional 'Current <br /> Cuarrent Rating(Amps) _ 200 <br /> hardware. .V611e <br /> • Up to four more large(240 VAC)loads can be managed when used in utility voltage Monitor(Fixed)* <br /> conjunction with Smart Management Modules(SMMs). -rick-up 60% <br /> -Dropout 65% <br /> • Electrically operated,mechanically-held contacts for fast,clean connections. ;Return tto t>tiliry� .: : _-T _ approz_i3 sec <br /> • Rated for all classes of load,100%equipment rated,both inductive and resin- Exercises bl weekly for 5 minutes ~ µ standard' <br /> • 2-pole,250 VAC contactors. 11LListed <br /> _ <br /> • Service equipment rated,dual coil design. Enclosure Type NEufA/UL 3R—" �- <br /> ed CtreuitBreakerPiotecl <br /> • Rated for both aluminum and copper conductors. Lug Range W - 250 MCM-#6 <br /> • Main contacts are silver plated or silver alloy to resist welding and sticking. <br /> • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mount- <br /> ing *Function flexibility. Exercise can be set to weekly or monthly <br /> Dimensions "" <br /> 200 Amps 120/240,1a <br /> Open Transition Service Rated <br /> Height Width Depth _ H, <br /> Hz <br /> H1 H2 W1 W2 <br /> in 26.75 30.1 10.5 13.5 6.91 <br /> mm 679.4 764.3 266.7 343.0 <br /> DEPTH I-V62 <br />