Laserfiche WebLink
23. Tamper-Resistant Receptacles,in accordance with 406.11 of the 2016 N.E.0 <br /> 24. In accordance with the Land .Development Code, Ibis shall be sodded before final at least 10 <br /> feet around the structure. <br /> 25. R403.5.3Hot water pipe insulation. - <br /> Insulatioh for hot Water pipe with'a minimum thermal resistance (R-value) of R-3 shall be applied to the <br /> following: <br /> Piping 31.inch (1.9.1 mm)and larger in nominal diameter. <br /> Piping serving more than one dwelling unit. <br /> Piping located outside the conditioned spade-.. <br /> Piping from the water heater to a distribution manifold-.- <br /> Piping located under a floor slab. <br /> Buried in piping,: <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25. Blower door test shall be provided.before C.O. <br /> 26. A cony-of the enerzy cacls shall be with'perniit at all times. <br /> 27. Conn of finalinsulation report shall be provided with permit before fnaL <br /> 28.No fence,-pool or screen enclosure is-issued with:this permit <br /> F.F.E.-Finished Floor Elevation <br /> F.B.0 Florida Building Code 61 Edition <br /> R.O.W.-Right of Way <br /> J A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2016) <br /> J <br />