My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-385
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-385
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2022 4:26:25 PM
Creation date
3/3/2022 4:26:24 PM
Metadata
Fields
Template:
Building Department
Company Name
DR HORTON
Building Department - Doc Type
Permit
Permit #
20-385
Building Department - Name
DR HORTON
Address
7779 DAVIE RAY DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PLOT PLAN <br /> DESCRIPTION:(AS FURNISHED) <br /> .LOT 36, BLOCK 9, ZEPHYR LAKES SUBDIVISION PHASES 1A, 2A, 2B, AND 4A <br /> AS RECORDED IN PLAT BOOK 80, PAGE(S) 37-48, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. <br /> ON LOT CALCULATIONS <br /> LOT = 5,750 SQ. FT. <br /> LIVING AREA = 1.048 SO. FT. <br /> GARAGE = 403 SQ. FT. <br /> ENTRY = 32 SO. FT. <br /> LANAI = 0 S0. FT. <br /> PATIO = 80 SQ. FT. <br /> DRIVEWAY - 440 SQ. FT. <br /> A/C PAD = 12 SQ. FT. <br /> WALKWAY - 31 SQ. FT. <br /> IMPERVIOUS - 369E <br /> = 2046 SQ. FT. <br /> SOD = 3.704 SQ. FT. a <br /> OFF LOT CALCULATIONS <br /> Line Table RIGHT OF WAY = 520 SO. FT. <br /> Une/ Direction rLength DRIVE APRON = 152 SQ. FT. <br /> PUBLIC S/W = 196 SO. FT. 1" = 30' <br /> L1 s0034'S2'W .00' SOD 172 SQ. FT. I GRC SCALE <br /> TOTALS 6 15 30 <br /> AREA = 6,270 SO. FT. <br /> DRIVEWAY = 592 SQ. FT. <br /> SIDEWALK = 227 SQ. Fr. <br /> SOD = 3.876 SQ. FT. <br /> I a <br /> /—\_APPROXIIAATE DEIJ14FA'IION LINE <br /> SCALED FROM FELIA MAP. <br /> LOT 37 <br /> BLOCK 9 I N <br /> 6 <br /> �1 ` r r✓, ` �� r g�SS I S84'2WO8'E <br /> S89'25 08.E 115.00 25.0• <br /> m W n i 5'D&AE <br /> 27.5'I 3 <br /> v a 46.7' W <br /> a' *W 0 <br /> o <br /> Uv O M Y �� °;'. /PROPOSED <br /> �.7 3FFB <br /> 1-< B.0' 1` 1`� ROBIE'H' 8> <br /> ¢ O ,y/m FINISHED FLOOR <br /> O <br /> W <br /> W O J J N ELEVA710N-89.50'ow <br /> O m �� A O a :r:�:��:�m:�:o:•• �aQ <br /> R Z 50.00 ..�1:- m c� I�> <br /> ;'::• of z_ LJ cc <br /> 50 <br /> a z 37.W. .0' N I 5; a <br /> p� N 5' D&AE .. .. I Nm Q p <br /> N89'25'08" �, 115.00' �y 8z <br /> _a: to <br /> ' LOT 35 I h <br /> BLOCK 9 is <br /> PREPARED FOR: <br /> B-11•HOMN' <br /> "Imo '6c'a's'Ru 'e4' a <br /> BUILDING SETBACKS <br /> FRONT: 22' <br /> GARAGE: 27' <br /> REAR: 13' <br /> SIDE: 5' <br /> SIDE STREET: 15' <br /> NOTES: <br /> LEGEND: <br /> 1. PROPOSED ELEVATIONS SHOWN HEREON ARE — •—•— BUILDING SETBACK LINE PI POINT OF INTERSECTION <br /> BASED ON THE APPROVED ENGINEERING PLANS PC POINT OF CURVATURE <br /> PREPARED BY HAMILTON ENGINEERING & — - — CENTERUNE PT POINT OF TANGENCY <br /> SURVEYING INC.. —--— RIGHT OF WAY LINE RP RADIUS POINT <br /> 2. ELEVATIONS ARE BASED ON NAVD 1988 PROPOSED ELEVATION PRC POINT OF REVERSE CURVATURE <br /> DATUM. iYP PERMANENT CONTROL POINT <br /> TYPIC <br /> PROPOSED DRAINAGE FLOW CS CONCRETE SLAB <br /> THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES ;r::'0i CONCRETE ER PLAT <br /> (P) CALCULATED <br /> ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF PB PLAT BOOK <br /> THE PROPOSED STRUCTURE. THE CONTRACTOR AND/OR A/C AIR CONDITIONER PGS PAGES <br /> OWNER ARE REQUIRED TO VERIFY ALL SETBACKS, BUILDING S/W SIDEWALK SQ. FT. SQUARE FEET <br /> DIMENSIONS, AND LAYOUT SHOWN HEREON PRIOR TO ANY F.E.M.A. FEDERAL EMERGENCY MANAGEMENT AGENCY <br /> CONSTRUCTION. F.I.R.M. FLOOD INSURANCE RATE MAP <br /> NAVD NORTH AMERICAN VERTICAL DATUM <br /> D&UE DRAINAGE&UTIUTY EASEMENT <br /> THIS IS NOT A SURVEY DE DRAINAGE EASEMENT <br /> THIS IS A PLOT PLAN ONLY &AE DRAINAGE&E UTILITY EASEACCESSUSUC EASEMENT <br /> FLOOD NOTE: I HAVE EXAMINED THE F.I.R.M.MAP NO.12101002931, SURVEYOR NOTES: <br /> UA 09/26/2014,AND FOUND THE SUBJECT PROPERTY APPEARS TO 1. THE SURVEYOR HAS NOT ABSTRACTED THE <br /> E PARTIALLY IN ZONE'K'&'A'.ZONE'X',AREAS DETERMINED TO BE LAND SHOWN HEREON FOR EASEMENTS, RIGHT <br /> DDEETERMINTSIDE ED TO BE SPECIAL AL Fl.�HAZARD AREAS SUBJECY To OF WAY, RESTRICTIONS OF RECORD WHICH <br /> INUNDATION BY THE IN ANNUAL CHANCE FLOOD EVENT,THE SURVEYOR MAY AFFECT THE TITLE OR USE OF THE LAND. <br /> MAKES NO GUARANTEES F.E.M.A. <br /> TO EN ABOVE INFORMATION.PLEASE 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN <br /> CONTACT THE LOCAL F. M.A.AGENT FOR VERIFICATION. <br /> LOCATED EXCEPT AS SHOWN. <br /> BEARING BASIS: <br /> BEARINGS SHOWN HEREON ARE BASED ON THE CENTERUNE OF DAME A!5hA 3. NOT VALID WITHOUT THE AUTHENTIC <br /> RAY DRIVE BEING N0034'52'E,PER PLAT. ELECTRONIC SIGNATURE AND THE AUTHENTIC <br /> (FIELD DATE:) REVISED: <br /> A M E IR I CAN ELECTRONIC <br /> FLORIDA LICENSED <br /> AND MAPPER. <br /> SU RV EY I N G `'1 L' DlgitallysignedbyJa—Wiloleman <br /> SCALE: 1'—30 FEET a"'" D AMUSSCAN food Y�gndo, <br /> -& MAPPING INC. ` � o <br /> -- - .MAPPING,INC.cn--1a W <br /> APPROVED BY: `B �� " •.-_ <br /> CERTIFICATION OF AUTHORIZATION NUMBER LB#6393 v` maim co ajboleman@asmcopoate. m FOR <br /> 190901 LOT 38, BLOCK 9 3191 MAGUIRE BOULEVARD, SUITE 200 '"+.::;_" Date:2020.05.2807e7:4so4'W THE <br /> JOB NO. ORLANDO. FLORIDA 32803 FIRM <br /> (407) 426-7979 DRAWN BY; DSB PLOT PLAN 05-20-2020 JSO WWWAMERICANSURVEYINGANDMAPPING.COM JAMES W. BOLEMAN PSM# 6485 DATE <br />
The URL can be used to link to this page
Your browser does not support the video tag.