Laserfiche WebLink
r <br /> • �9 <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E.. shall be a minimum of 8" above the road elevation and an engineered site plan. <br /> I Lots shall be graded to comply with R401.3 of the F.B.C. <br /> 3: Compaction test required if 24"or more of fill.dirt is brought in at any one place. <br /> 4. Tie in survey required before pouring concrete. <br /> 5: Driveways require a R.O:W. use_ permit_. All 4 sides.of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6. All setbacks shall be-met. <br /> 7. All Pp <br /> ro ertY markers shall be uncovered and marked at time of first inspection. <br /> _ . . _ <br /> 8: All A.D.A.requirements shall be met: <br /> 9. No electric, plumbing, mechanical, or framing shall be covered without an inspection and . <br /> approval first. <br /> 10: All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation). <br /> 11. Appliances shall not be installed in a location where subject to mechanical damage unless <br /> protected by approved barriers. M303:4 of the F.B.0 <br /> 12-Water heaters shall comply with section P607.3 of the-F.B.C. <br /> B.-Foundation supports for A/.0 units shall be raised at least 3" above finished grade. -M1308.1 . <br /> 14: Return air in all bedrooms. F.B.C. M1620:4 <br /> 15. Smoke detectors are to be installed in accordance with R313.1 of.the.F.B.C. <br /> 16.All glazing requirements are to be in accordance.with R308.4 of the R&C: <br /> 17. All means of egress are.to be in accordance with R311 of the F.B.C. <br /> 18. "Green gypsum board"shall not be used as a backer-in showers or tubs. R702.4.2 F.B.C. <br /> 10. Combination' type AFCI breakers are required at all locations requiring an AM type breaker. <br /> 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating <br /> or appliances or an attached garage. They shall be installed in accordance with the F.B.C: <br /> 21. All plumbing,mechanical, and electrical shall be separate from unit to unit: This includes all <br /> underground plumbing and electric. <br /> 22. All 2016 N.E.C. Codes will be enforced. <br />