My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-404
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-404
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2022 4:36:50 PM
Creation date
3/3/2022 4:36:49 PM
Metadata
Fields
Template:
Building Department
Company Name
DR HORTON INC
Building Department - Doc Type
Permit
Permit #
20-404
Building Department - Name
DR HORTON INC
Address
35575 BURMA REED DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
D <br /> Q <br /> ti <br /> 1 � <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E..shall be a minimum of 8" above the road elevation and an engineered site plan. <br /> 2: Lots shall be graded to comply with R401:3 of the F.B.C.- <br /> I. Compaction test required if 24"or more of fill dirt is brought in at any one place. <br /> 4: Tie in survey required before.pouring concrete. <br /> 5: Driveways require.a R.O.W. use permit. All 4 sides of driveway_ thru the sidewalk shall have <br /> expansion material. <br /> 6: All setbacks shall be met. <br /> 7: All property markers shall be uncovered.-arid marked at time of first inspection. <br /> 8: All A.D.A. requirements shall be met; <br /> 9: No electric,.plumbirg;mechanical, or framing shall.be covered without an inspection.and <br /> approval f rst. <br /> 10: All Garages shall-comply with section R302.6 of the F.B:C. (Fire Separation).: <br /> :1.1.Appliances shall not-be installed in a location where subject to mechanical damage unless <br /> protected by:approved barriers. M303.4 of the RB.0 <br /> 12. Water heaters'shall comply with section P607.3 of the F:B.C. <br /> 13: Foundation supports for A/C units shall be raised at least 3" above finished grade. M 1308.:1. <br /> 14: Return air in all bedrooms. F.B.C. M1620:4 <br /> 1.5. Smoke detectors.are to he installed in accordance with R313:1 'of the F.B.C. <br /> 16: All glazing requirements are to be.in accordance with R308:4 of the F.B:C: <br /> 17. All means of egress are to be in accordance with R311 of the F.B.C. <br /> 18. "Green gypsum,board" shall not be used as a backer in showers or tubs. R702:4.2 F.B.C. <br /> 19. Combination-type AFCI breakers are required at all locations requiring an AFCI.type breaker, <br /> 20. C:arbOn monoxide alarms will be required in new construction that uses fossil-burning heating. <br /> or appliances or an attached garage. They shall be installed in accordance with the F.B.C: <br /> 21. All plumbing,mechanical; and electrical shall b.e separate from unit to unit: This includes all <br /> underground plumbing and electric. <br /> M All 2016 N:E.C. Codes will be enforced: <br />
The URL can be used to link to this page
Your browser does not support the video tag.