Laserfiche WebLink
y <br /> I <br /> '23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2016 N.E.0 <br /> .24. In accordance with the Land Development Code, lots shall be sodded before final at least 10 <br /> feet around the structure. <br /> 25-. R403.5.3Hot water pipe insulation <br /> Insulation for hot.water'pipe-with a minimum thermal resistance (R-value) of R-3 shall.be applied to the <br /> following: <br /> Piping.3/:inch (19:1 mm) and larger in.nominal diameter. <br /> Piping,serving more than one dwelling unit. <br /> Piping located outside the conditioned space: <br /> Piping from the.:water heater to a-distribution manifold. <br /> Piping located under a floor slab.- <br /> Buried in piping. <br /> Supply and return-piping in recirculation systems other than demand recirculation systams. <br /> 25. Blower door test shall be provided before C.O. <br /> 26.A copy of the-enerQy eacls shall be with permit at all times <br /> 27.Copy of final'insulation reoort shall-be provided with Permit before fnaL <br /> 28. No.fence. Wool or enclosure :is-issued with-this berrnix' <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C-Florida Building Code 6ffi Edition <br /> R.O.W.-Right of Way- <br /> A.D.A.-Americans with Disabilities Act- N.E.C.-National Electric Code(2016) <br />