Laserfiche WebLink
T. <br /> 1� <br /> D <br /> Q <br /> ti A <br /> i <br /> 1 � <br /> Single Family DWe'lling <br /> Plan Review Comments <br /> 1. F:RE:.shall be a mimmum of 8" above the road elevation and an engineered site plan. <br /> 2 Lots shall be graded to comply with R401.3 of the F.B.C. <br /> 3: Compaction test required if 24".6r more of fill dirt is brought in at any one place. <br /> 4: Tie in survey required before pouring concrete. <br /> 5; Driveways require.a R,O.W. use permit. All 4 sides of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6: All setbacks shall be met. <br /> 7. All,property markers shall be uncovered,and marked at time:of first inspection. <br /> 8: All A.D.A.requirerrierits shall be met: <br /> 9. No electric,plumbing;mechanical, or.framing shall be covered without an inspection.and <br /> approval first: <br /> 10: All Garages_shall comply With section R302.6 of the F.B.C. (Fire Separation): <br /> 11. Appliances shall not be installed in a location where subject to mechanical damage unless <br /> protected by.approved barriers. M303.4 of the F.B.0 <br /> 12. Water heaters shall comply with section P607.3 of the F.B.C: <br /> 13: Foundation supports for A/C units.shall.b.e raised at least 3" above finished grade. M1308:1 <br /> 14. Return air in all bedrooms. F.B.C. M1620:4 <br /> 15. Smoke detectors are to be installed in accordance with.R313:1 of the.F.B.C. <br /> 16.All glazing requirements are to be in accordance with R308:4 of the F.B.C. <br /> 17. All means of egress are to be in accordance with R311 of the F.B.C. <br /> 18."Green:gypsum board" shall not be used as a backer in showers or tubs. R702:4.2 F.B.C. <br /> 19:-Combination-type AFCI.breakers are.required at all locations.requiring:air AM type breaker-.' <br /> 20. Carbon monoxide alarms will.be required in new construction that uses fossil-burning heating. <br /> or appliances or an attached garage.' They shall be installed in accordance with the F.B.C: <br /> 21..All.plumbing,iechanical; and electrical shall be separate from unit to unit: This includes all <br /> underground.pI' ' b- and electric. <br /> 22. All 2016 N.-H.C. Codes will be enforced. <br />