Laserfiche WebLink
c <br /> PARTS LIST MIN. EDGE REVISIONS <br /> NO. PART NUMBER DESCRIPTION SUBSTRATE DISTANCE SEE REv DESCRIPTION DATE lTPROVED <br /> 1 3" IMPACT MULLION, ALUMINUM BY OTHERS NOTES THIS PAGE SEE NOTES C REVISED PER NEW REQUIREMENTS 01/12/18 R.L.' <br /> 2 05-053 CLIP r����/�/i�fr��/�jrij� r/i�r FOR ANCHOR TYPE <br /> SEE NOTES <br /> FOR MIN. EMS. <br /> 2 ANCHORING NOTES: <br /> 1.375" <br /> 1 1) FOR ANCHORING INTO MASONRY USE 3/16" TAPCONS WITH SUFFICIENT <br /> .15" � 1.075" #10 TEK SCREWS LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH <br /> 2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS. <br /> DETAIL A AND INSTALLATION DETAILS. <br /> TOP AND BOTTOM CLIP INSTALLATION 2) FOR ANCHORING INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD <br /> SCREW WITH SUFFICIENT LENGTH TO ACHIEVE A 1 3/8" MINIMUM <br /> EMBEDMENT INTO SUBSTRATE WITH 1/2" MINIMUM EDGE DISTANCE. LOCATE <br /> 2.8 1.55" SEE NOTES ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. <br /> fF6�OR MIN. EMS. <br /> 3) FOR ATTACHING WINDOW UNITS TO MULLION USE #10 TEK SELF TAPPING <br /> .625" SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A MINIMUM EMBEDMENT OF <br /> THREE THREADS PAST THE MULLION WALL WITH 1/2" MINIMUM EDGE <br /> � DISTANCE. LOCATE SCREWS AS SHOWN IN ELEVATIONS AND INSTALLATION <br /> SEE NOTES FOR#10 TEK SCREWS � DETAILS. <br /> �� ANCHOR TYPEO3"IMPACTMULLION �` 4) FOR ATTACHING VERTICAL MULLION TO HORIZONTAL MULLION USE #10 TEK <br /> 16063-T6ALUMINUM � SELF TAPPING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A MINIMUM <br /> �� EMBEDMENT OF THREE THREADS PAST THE MULLION WALL. LOCATE SCREWS <br /> SUBSTRATE� AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. <br /> � BY OTHERS <br /> 5) FOR WINDOW UNITS ANCHORING SCHEDULE REFER TO WINDOW APPROVED <br /> INSTALLATION INSTRUCTIONS. <br /> 6.05" MIN. EDGE 6) ALL FASTENERS TO BE CORROSION RESISTANT. <br /> ` DISTANCE SEE <br /> 1.75" 1.75" ` NOTES THIS PAGE 7) INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH <br /> 375" 375" ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS <br /> SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE <br /> 375" <br /> DETAIL B MINIMUM STRENGTH SPECIFIED BELOW. <br /> SIDE CLIP INSTALLATION 8) INSTALLATION ANCHOR CAPACITIES FOR PRODUCTS HEREIN ARE BASED <br /> ON SUBSTRATE MATERIAL WITH THE FOLLOWING PROPERTIES: <br /> A. WOOD — MINIMUM SPECIFIC GRAVITY OF G=0.42 <br /> 1.49 .74 B. CONCRETE — MINIMUM COMPRESSIVE STRENGTH OF 3,200 PSI. <br /> C. MASONRY — STRENGTH CONFORMANCE TO ASTM C-90, GRADE N, <br /> TYPE 1 (OR GREATER). <br /> 1.015" 01/4" #10 TEK SCREWS 1 <br /> SIGNED:01/12/2018 <br /> VIWINTzaoo RvCH ND0WS IN oe8 DRDEDOORS `\\\ S R��LI0�ii,/� <br /> PADUCAH, KY 42003-0588 �� `� cEN' 9 <br /> 3.125" v;,�\ <br /> 2 1 SHORELINE 3" IMPACT MULLION *• 0 9t." <br /> VERTICAL AND HORIZONTAL7 — <br /> INSTALLATION DETAILS � �� <br /> L .125" <br /> #10 TEK SCREWS �70, TAT OF. 'gjz <br /> DRAWN: DWG NO. REV ��0��•,'��•1pRl�Q;�'\ \� <br /> DETAIL C R.L. 08-00237 C <br /> HORIZONTAL AND VERTICAL MULLION SCALE DATE SHEET <br /> OCLIP NTS 0L. OS L. TO 5 OF 5 <br /> 2 INTERSECTION CLIP INSTALLATION / / <br /> sO63-T6ALUMINUM LOMAS P.E. <br /> 1432WOODFORDRDD LEWIS VILLE,NC27023 Luis R. Lamas P.E. <br /> 434-666-0609 nlomas@ldomaspe.mm FL No.: 62514 <br />