My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-436
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-436
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2022 6:54:41 AM
Creation date
3/4/2022 6:54:40 AM
Metadata
Fields
Template:
Building Department
Company Name
LINKS AT CALUSA SPRINGS LLC
Building Department - Doc Type
Permit
Permit #
20-436
Building Department - Name
LINKS AT CALUSA SPRINGS LLC
Address
6910 SHELBY LYNN WAY
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE <br /> FORM R405-2017 COPY <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: KHO1464 Ashmere(TAM)LOT 77 Builder Name: K Hovnanian Homes <br /> Street: 6910 Shelby Lynn Way Permit Office: City of Zephyrhills <br /> City;State,Zip: Zephyrhills,FL, 33642 Permit Number: <br /> Owner: - Jurisdiction: <br /> Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1415.6 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1248.00 ft2 <br /> b.Frame-Wood,Adjacent R=11.0 167.56 ft2 <br /> 3. Number of units,if multiple family 1 c.N/A R= ft2 <br /> 4. Number of Bedrooms 3 d.N/A R= ft2 <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1464.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1464.00 ft2 <br /> 6. Conditioned floor area above grade(ft2) 1464 b.N/A R= ft2 <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 <br /> 11.Ducts R ft2 <br /> 7. Windows(134.9 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Main 6 200 <br /> a. U-Factor: Dbl,U=0.34 78.75 ft2 <br /> SHGC: SHGC=0.23 <br /> b. U-Factor: Dbl,U=0.63 40.00 ft2 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 22.3 SEER:15.00 <br /> c. U-Factor: Dbl,U=0.34 16.19 ft2 <br /> SHGC: SHGC=0.29 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft2 a.Electric Heat Pump 23.2 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.000 ft. <br /> Area Weighted Average SHGC: 0.264 14.Hot water systems <br /> 8. Floor Types (1464.0 sqft.) Insulation Area a.Electric Cap:50 gallons <br /> a.Slab-On-Grade Edge Insulation R=0.0 1464.00 ft2 b. Conservation features EF:0.950 <br /> b.N/A R= ft2 None <br /> c.N/A R= ft2 15.Credits Pstat <br /> Glass/Floor Area: 0.092 <br /> Total Proposed Modified Loads: 50.54 PASS <br /> Total Baseline Loads: 50.31 <br /> I hereby certify that the plans and specifications covered by Review of the plans and EVE STAT <br /> this calculation are in compliance with the Florida Energy specifications covered by this ,y� <br /> Code. calculation indicates compliance <br /> with the Florida Energy Code. <br /> PREPARED BY: Before construction is completed <br /> DATE: ?22 nn this building will be inspected for � <br /> compliance with Section 553.908 <br /> hereby certify that this building,as designed, is in compliance Florida Statutes. <br /> with the Florida Energy Code. G'Orjy � <br /> OWNER/AGENT: .Scar 0kRAM-cy BUILDING OFFICIAL: <br /> DATE: 7/22/2020 DATE: <br /> - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.3.2.1. <br /> -Compliance requires an Air Baffler and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an <br /> envelope leakage test report with envelope leakage no greater than 5.70 ACH50(R402.4.1.2). <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.060 Qn for whole house. <br /> 7/22/2020 2:14 PM EnergyGauge@)USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.