Laserfiche WebLink
STATE COPY <br /> FORM R405-2017 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: KHO1830 Dupont(TAM) Builder Name: K Hovnanian Homes <br /> Street: 6902 Shelby Lynn Way Permit Office: City of Zephyrhills <br /> City,State,Zip: Zephyrhills,FL, 33542 Permit Number: <br /> Owner: Jurisdiction: <br /> Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1687.1 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1406.90 ft2 <br /> b.Frame-Wood,Adjacent R=11.0 280.22 ft2 <br /> 3. Number of units,if multiple family 1 c.N/A R= ft2 <br /> 4. Number of Bedrooms 4 d.N/A R= ft2 <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1830.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1830.00 ft2 <br /> 6. Conditioned floor area above grade(ft2) 1830 b.N/A R= ft2 <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 <br /> 11.Ducts R ft2 <br /> 7. Windows(158.3 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Main 6 190 <br /> a. U-Factor: Dbl,U=0.34 101.94 ft2 <br /> SHGC: SHGC=0.23 <br /> b. U-Factor: Dbl,U=0.63 40.20 ft2 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 26.9 SEER:15.00 <br /> c. U-Factor: Dbl,U=0.34 16.19 ft2 <br /> SHGC: SHGC=0.29 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft2 a.Electric Heat Pump 28.0 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.000 ft. <br /> Area Weighted Average SHGC: 0.259 14.Hot water systems <br /> 8. Floor Types (1830.0 sqft.) Insulation Area a.Electric Cap:50 gallons <br /> EF:0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1830.00 ft2 b. Conservation features <br /> b.N/A R= ft2 None <br /> c.N/A R= ft2 15.Credits Pstat <br /> Glass/Floor Area: 0.087 Total Proposed Modified Loads: 60.31 PASS <br /> Total Baseline Loads: 60.03 <br /> I hereby certify that the plans and specifications covered by Review of the plans and O TxE ST,q?F <br /> this calculation are in compliance with the Florida Energy specifications covered by this <br /> Code. calculation indicates compliance �`��i„ '' ,s;��•`` ri' <br /> with the Florida Energy Code. � rr,,,� %., .;.,•-.�,••;,.. ,� O <br /> PREPARED BY: Before construction is completed r <br /> DATE: 7-22 2aOthis building will be inspected for <br /> compliance with Section 553.908 <br /> I hereby certify that this building, as designed, is in compliance Florida Statutes. <br /> with the Florida Energy Code. OD.WE' <br /> OWNER/AGENT: BUILDING OFFICIAL: <br /> DATE: 7/22/2020 DATE: <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.3.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an <br /> envelope leakage test report with envelope leakage no greater than 6.00 ACH50(R402.4.1.2). <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.060 Qn for whole house. <br /> 7/22/2020 11:27 AM EnergyGauge(D USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 4 <br />