Laserfiche WebLink
' 21 Tamper- Resistant Receptacles in accordance with 406.11 of the 2016 N.E.0 <br /> 24. In accordance with the Land Development Code, lots shall be sodded before final at least 10 <br /> feet around the structure. <br /> 25.. R403.5.Mof water pipe insulation <br /> Insulation for hot.water-pipe with a minimum thermal resistance (R-value) of R-3 shall be applied to the <br /> following: . <br /> Piping 31,inch'(19.1 mm)and larger in nominal diameter.; <br /> Piping serving rriore than:one dwelling unit. <br /> Piping located outside the conditioned space: <br /> Piping from the water-heater to a distribution manifold. <br /> Piping.located under a floor slab. <br /> Buried in piping. <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25: Blower door test shall be provided Before C.O: <br /> 26.A copy ofthe enerzy cacls shall be with permit at all times. <br /> 27. Copy of final'insulation report shall be provided with permit before fn iL <br /> 28.No fenee, pool or screen'enclosure :is issued withIhis-permit. <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C-Florida Building Code 6t'Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code (2016) <br />