My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-444
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-444
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2022 7:02:14 AM
Creation date
3/4/2022 7:02:13 AM
Metadata
Fields
Template:
Building Department
Company Name
LINKS AT CALUSA SPRINGS LLC
Building Department - Doc Type
Permit
Permit #
20-444
Building Department - Name
LINKS AT CALUSA SPRINGS LLC
Address
6918 SHELBY LYNN WAY
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE COPY <br /> FORM A405-2017 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: KH02321 Emerald(TAM) Builder Name: K Hovnanian Homes <br /> Street: 6918 Shelby Lynn Way Permit Office: City of Zephyrhills <br /> City,State,Zip: Zephyrhills,FL, 33542 Permit Number: <br /> Owner: Jurisdiction: <br /> Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(2455.6 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1178.70 ft, <br /> b.Concrete Block-Int Insul,Exterior R=4.1 936.00 ft' <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 340.89 ft' <br /> 4. Number of Bedrooms 5 d.N/A R= ft' <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1354.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1354.00 ft' <br /> 6. Conditioned floor area above grade(ft� 2321 b.N/A R= ft' <br /> Conditioned floor area below grade(ft� 0 c.N/A R= ft' <br /> 11.Ducts R ft' <br /> 7. Windows(197.5 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:2nd Floor 6 233 <br /> a. U-Factor: Dbl,U=0.34 121.19 ft' <br /> SHGC: SHGC=0.29 <br /> b. U-Factor: Dbl,U=0.63 40.00.ft' 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 33.1 SEER:15.00 <br /> c. U-Factor: Dbl,U=0.34 36.29 ft' <br /> SHGC: SHGC=0.23 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft' a.Electric Heat Pump 32.6 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 3.026 ft. <br /> Area Weighted Average SHGC: 0.285 14.Hot water systems <br /> a.Electric Cap:50 gallons <br /> 8. Floor Types (2321.0 sqft.) Insulation Area EF:0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 968.00 ft' b. Conservation features <br /> b.Floor Over Other Space R=0.0 967.00 ft2 None <br /> c.other(see details) R= 386.00 ft' 15.Credits Pstat <br /> Glass/Floor Area: 0.085 Total Proposed Modified Loads: 73.83 PASS <br /> Total Baseline Loads: 73.53 <br /> I hereby certify that the plans and specifications covered by Review of the plans and ZiE ST.gr� <br /> this calculation are in compliance with the Florida Energy specifications covered by this <br /> Code. calculation indicates compliance uq ' <br /> �i with the Florida Energy Code. <br /> PREPARED BY: ll _��� Before construction is completed 1:4 � <br /> DATE: 7- 9-200 this building will be inspected for <br /> compliance with Section 553.908 * '1 <br /> hereby certify that this building, as designed, is in compliance Florida Statutes. <br /> with the Florida Energy Code. COD WEB" . <br /> OWNER/AGENT: SCWalVR2 VefT(/ BUILDING OFFICIAL: <br /> DATE: 7/22/2020 DATE: <br /> - Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as <br /> certified factory-sealed in accordance with R403.3.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an <br /> envelope leakage test report with envelope leakage no greater than 5.90 ACH50(R402.4.1.2). <br /> - Compliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.060 On for whole house. <br /> 7/22/2020 1:47 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.