Laserfiche WebLink
23. Tamper- Resistant Receptacles in accordance with 406.41 of the.2016 N.E:C <br /> 24. In accordance with the Land Development Code,lots_ shall be sodded before final_ at least 10 <br /> feet around the structure. <br /> 25. R403.5.Mot wate. pipe insulation, <br /> Insulation for hot water pipe with'a minimum thermal resistance (R-value) of R-3 shall be applied to the . <br /> following: <br /> Piping V. inch (19.1 mm)and larger in.:nominal diameter.. <br /> Piping.serving more than_one dwelling unit: <br /> Piping located outside'the conditioned space... <br /> Piping from the water heater to a distribution manifold. <br /> Piping located under'a floor slab. <br /> Buried in piping. <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25. Blower door test shall be provided before C.O. <br /> 26.A copy of the enerpy cacls shall be with-permit at all times <br /> 27. Copy of rnal insulation report shall be provided ivith permit before fnab <br /> 28. No fence,pool or screen enclosure Js issued: th this-permit <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C- Florida Building Code 6 h Edition <br /> R.O.W.-Right of Way <br /> A.D:A.-Americans with Disabilities Act N.E.C.-National Electric Code(2016) <br />