My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-446
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-446
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2022 7:04:53 AM
Creation date
3/4/2022 7:04:52 AM
Metadata
Fields
Template:
Building Department
Company Name
LINKS AT CALUSA SPRINGS LLC
Building Department - Doc Type
Permit
Permit #
20-446
Building Department - Name
LINKS AT CALUSA SPRINGS LLC
Address
6888 SHELBY LYNN WAY
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE Copy <br /> FORM R405-2017 - <br /> FLORIDA ENERGY EFFICIENCY;CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: KH02321 Emerald(TAM) Builder Name: K Hovnanian Homes <br /> Street:, 6888 Shelby Lynn Way Permit Office: City of Zephyrhills <br /> City,State,Zip: Zephyrhills,FL, 33542 Permit Number: <br /> Owner: Jurisdiction: <br /> Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(2455.6 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family <br /> a.Frame-Wood,Exterior R=11.0 1178.70 ft2 <br /> b.Concrete Block-Int Insul,Exterior R=4.1 936.00 ft2 <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 340.89 ftz <br /> 4. Number of Bedrooms 5 d.N/A R= ft2 <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1354.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1354.00 ft2 <br /> 6. Conditioned floor area above grade(ft2) 2321 b.N/A R= ft2 <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 <br /> 11.Ducts R ft2 <br /> 7. Windows(197.7 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:2nd Floor 6 233 <br /> a. U-Factor: Dbl,U=0.34 121.19 ft2 <br /> SHGC: SHGC=0.29 <br /> b. U-Factor: Dbl,U=0.63 40.20 ft2 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 33.1 SEER:15.00 <br /> c. U-Factor: Dbl,U=0.34 36.29 ft2 <br /> SHGC: SHGC=0.23 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft2 a.Electric Heat Pump 32.6 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.000 ft. <br /> Area Weighted Average SHGC: 0.285 14.Hot water systems <br /> a.Electric Cap:50 gallons <br /> B. Floor Types (2321.0 sqft.) Insulation Area <br /> EF:0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 968.00 ft2 b. Conservation features <br /> b.Floor Over Other Space R=0.0 967.00 ft2 None <br /> c.other(see details) R= 386.00 ft2 15.Credits Pstat <br /> I <br /> Glass/Floor Area: 0.085 Total Proposed Modified Loads: 73.88 PASS <br /> Total Baseline Loads: 73.53 <br /> hereby certify that the plans and specifications covered by Review of the plans and � T SrATt� <br /> this calculation are in compliance with the Florida Energy specifications covered by this <br /> Code. calculation indicates compliance <br /> with the Florida Energy Code. <br /> PREPARED BY: LL�1- /� Before construction is completed <br /> 2_ this building will be inspected for <br /> DATE: �2c ' 9 P <br /> compliance with Section 553.908 <br /> Florida Statutes. es, <br /> hereby certify that this building,as designed, is in compliance 1j: <br /> with the Florida Energy Code. CAD.-TPE <br /> OWNER/AGENT: ScW0L1V2we4'a1 BUILDING OFFICIAL: <br /> DATE: 7/22/2020 DATE: <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.3.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an <br /> envelope leakage test report with envelope leakage no greater than 5.30 ACH50(R402A.1.2). <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.060 Qn for whole house. <br /> 7/22/2020 1:32 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.