Laserfiche WebLink
FORM R405-2017... <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation Residential Performance Method <br /> Project Name: cedar BuilderName: Mario's Air Conditioning and Heating Inc. <br /> Street: 6462 Bradford Woods Dr Permit Office: (;19�(�i 7,��1�j/ 1r�City,State,Zip: Zephyrhills,FL,33542 Permit Number: `}'t' _7_ l <br /> Owner: CEDAR Jurisdiction: ���� //DD <br /> Des'ignLocation: FL,Tampa County: pas`co`tF�n�ClimateZone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types (1902.2 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1544.30 ftZ <br /> b.Frame-.Wood,Adjacent R=13.0 357.83 ftZ <br /> 3. Number of units,if multiple family 1 c.N/A R= ftZ <br /> 4. Number of Bedrooms 3 i d.N/A R=' ftZ. <br /> 10.Ceiling Types (1698.0 sqft.) Insulation Area <br /> 5. Is this a worst case? Yes a..Under Attic(Vented) R=30.0 1698.00 ftZ <br /> 6. Conditioned floor area above grade(ftZ) 1662 b.N/A R= ftZ <br /> Conditioned floor area below grade(ftZ) 0 c.N/A R=. ftZ <br /> 11.Ducts R ftZ <br /> 7. Windows(222.4 sqft.) Description Area a.Sup:Attic,Ret:Attic;AH:,LIVING-KIT-DIN 6 300 <br /> a. U-Factor: : Dbl,U=0.35 174.43 ftZ <br /> SHGC: : SHGC=0.29 <br /> b. U-Factor: Dbl,U=0.63 48.00 ftZ 12.Cooling system_ s kBtu/hr Efficiency . <br /> SHGC: SHGC=0.32 a.Central Unit 30.0 SEER:15.00 <br /> c. U-Factor: N/A : ftZ <br /> SHGC:, 13.Heating systems kBtutbr Efficiency <br /> d. U-Factor: N/A ftZ a.Electric Heat Pump 24.0 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 0.000 ft. <br /> Area Weighted Average SHGC: 0.29.6 14.Hotwatersystems <br /> a.Electric Cap:50 gallons <br /> 8. Floor Types' (1698.0 sqft.) Insulation Area EF:0.920 <br /> -.a.Slab-On-Grade Edge Insulation R=0.0 1698.00 ftZ b.Conservation features <br /> b.N/A R= ftZ None <br /> c.N/A R= ftZ 15..Credits Pstat <br /> i <br /> Glass/Floor Area: 0.134 Total Proposed Modified Loads: 59.65 �7�7���+�+ <br /> Total Baseline Loads: 61.76 <br /> I hereby certify that the plans and specifications covered by Review of the plans and L ST,�p� <br /> this calculation are in compliance with the Florida Energy. specifications covered by this ; O� <br /> Code. calculation indicates compliance - <br /> - . with the Florida Energy Code. <br /> PREPARED BY: 41� Z61 .'Before construction is completed ` <br /> DATE: 07/20/2020 this buildin will be ins ected for T 7' <br /> 9 p <br /> compliance with Section 553.908 * "_ <br /> I hereby certify that this building, as designed, is in compliance Florida Statutes. - <br /> with the Florida Energy Code. COb W8' � <br /> OWNER/AGENT: Snezana Gurcinovska BUILDING OF CI L: <br /> DATE: 7/20/2020 DATE: � II.7n <br /> Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.3.2:1: <br /> -Compliance requires an Air:Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires <br /> amenvelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). <br /> 7/20/2020'10:16 AM EnergyGaugeO USA 6.0.02(Rev.1)7 FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 5 <br />