Envelope Leakage Test Report (Blower Door Test) <br /> 9 <br /> Residential Prescriptive, Performance or ERI Method Compliance <br /> 2017 Florida Building Code, Energy Conservation, 6th Edition <br /> F <br /> Jurisdiction: Permit#: <br /> Job Information <br /> Builder: Mario's Air Conditioning and 1­10dingilr dty: Lot: NA <br /> Address: 6462 Bradford Woods Dr <br /> City: Zephyrhills State: FL Zip: 33542 <br /> Air Leakage Test Results- Passing results must meet either the Performance, Prescriptive, or ERI Method <br /> O. PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air <br /> changes per hour at a pressure of 0.2 inch w.g.(50 Pascals)in Climate Zones 1 and 2. <br /> 0, PERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an,air leakage rate of not exceeding <br /> the selected ACH(50)value,as'shown on Form R405-2017(Performance)or R406-2017(ERi),section labeled as infiltration,sub-section ACH50. <br /> A CH(50)specified on Form R405-2017-Energy Ca/c(Performance)or R406-2017(ERI): 7,000 <br /> x 60 _ 15623 = Method for calculating buildinq volume: <br /> CFM(50) Building Volume ACH(50) O Retrieved from architectural plans <br /> PASS 0 Code software calculated <br /> When ACH(50) is less than 3, Mechanical Ventilation installation O Field measured and calculated <br /> must be verified by building department. <br /> R402.4.1.2 Testing.Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 Pascals). <br /> Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statues.or individuals licensed as set forth in Section <br /> 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and <br /> provided tothecode official Testing shall be performed at any time after creation of all penetrations of the building thermalenvelope. <br /> During testing: <br /> 1.Exteriorwindows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration <br /> control measures. <br /> 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control <br /> measures. <br /> 3.Interior doors,if installed at the time of the test,shall be open. <br /> 4.Exterior doors forcontinuous ventilation systems and heat recovery ventilators shall be closed and sealed. <br /> 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. <br /> 6.Supply and return registers,if installed at the time of the test,shall be fully open. <br /> Testing Company <br /> Company Name: Phone: <br /> I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code <br /> Energy Conservation requirements according to the compliance method selected above. <br /> Signature of Tester: Date of Test: <br /> Printed Name of Tester: <br /> License/Certification#: Issuing Authority: <br /> 7/20/202010:16:31 AM EnergyGauge®USA 6.0.04(Rev.1)-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 <br />