My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-447
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-447
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2022 7:05:46 AM
Creation date
3/4/2022 7:05:44 AM
Metadata
Fields
Template:
Building Department
Company Name
PULTE HOME COMPANY LLC
Building Department - Doc Type
Permit
Permit #
20-447
Building Department - Name
PULTE HOME COMPANY LLC
Address
6462 BRADFORD WOODS DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Manual S Compliance Report Job: <br /> - - wrightsoftQ Date: Feb 26,2019 <br /> Entire House By: <br /> Mario's Air Conditioning and Heating Inc. <br /> 9213 Denton Ave,Hudson,FL 34667 Phone:727-843-9598 Fax:727-645-6957 Email:infodmariosac.com Web:www.madosac.com <br /> Project • • <br /> For: CEDAR, PULTE HOMES <br /> 6462 Bradford Woods Dr,Zephyrhills, FL <br /> - Cooling Equipment <br /> Design Conditions <br /> Outdoor design DB: 91.4°F Sensible gain: 25179 Btuh Entering coil DB: 76.VF <br /> Outdoor design WB: 77.2°F Latent gain: 3161 Btuh Entering_ coil WB: 64.4°F <br /> Indoor design DB: 75.0°F Total gain: 28341 Btuh <br /> Indoor RH: 55% Estimated airflow: 946 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Lennox Model: 14HPX-030-230-22+CBA27UHE-030-230*++TDR <br /> Actual airflow: 946 cfm <br /> Sensible capacity: 25500 Btuh 101% of load <br /> Latent capacity: 4500 Btuh 142% of load <br /> Total capacity: 30000 Btuh 106% of load SHR: 85% <br /> Heating Equipment <br /> Design Conditions <br /> Outdoor design DB: 42.9°F Heat loss: 19571 Btuh Entering coil DB: 69.7°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: . Split ASHP <br /> Manufacturer: Lennox Model: 14HPX-030-230-22+CBA27UHE-030-230*++TDR <br /> Actual airflow: 946 cfm <br /> Output capacity: 26000 Btuh 133% of load Capacity balance: 36 °F <br /> Supplemental heat required: 0 Btuh Economic balance: -99 °F <br /> Backup equipment type: Elec strip <br /> Manufacturer: Model: <br /> Actual airflow: 946 cfm <br /> Output capacity: 5.4 kW 95% of load Temp. rise: 50 °F <br /> Meets all requirements of ACCA Manual S. <br /> wraightsoft- 2020-Jul-2010:13:42 <br /> ...�•, ...�,s t. Right-Suite®Universal 2018 18.0.32.RSU18255 Page 1 <br /> rn+ \OneDrive\Pulte Homes\LOAD CALC FILES\cedar.rup Calc=MA Front,Door faces: E <br />
The URL can be used to link to this page
Your browser does not support the video tag.