Laserfiche WebLink
'1 <br /> i <br /> D <br /> Q <br /> 1 � � <br /> i 1 ' <br /> r. <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E.. shall be a minimum of 8" above-the road elevation and an engineered_ -site plan. <br /> 2. _Lots shall be graded to comply with R401.3 of the F.B.C. <br /> 3.. . Compaction test required.if 24" or more of fill dirt is brought in at any one-place. <br /> 4: Tie in survey required before pouring concrete. <br /> 5. Driveways require a R.O.W. use permit. All 4 sides of driveway thru the sidewalk_shall have <br /> expansion material. <br /> 6. All setbacks shall be met. <br /> -7. All property markers shall be uncovered.and marked at time of first inspectioni. <br /> 8. All A.D.A. requirements shall be.met: <br /> 9.. No electric,plumbing;mechanical, or(framing shall be covered without an inspection and . <br /> approval first: <br /> 10. All Garages shall comply With section R302.6 of the F.B.C. (Fire Separation). <br /> 11. Appliances shall not be installed in a location where subj ect.to mechanical damage unless <br /> protected by approved barriers. M303:4 of the F.B.0 <br /> 12-Water heaters shall comply with section P607.3 of the F.B."C. <br /> 13."Foundation supports for A/C units,shall.be raised at least 3" above finished grade. M1308.1 . <br /> 14: Return air in all bedrooms. F.B.C. M1620.4 <br /> 1.5. Smoke detectors.are to be installed in accordance with R313-1 of the.F.B.C. <br /> 16. All glazing requirements are to be in accordance with R308A of the F.B:C: <br /> 17. All means of egress are to be in accordance with R311 of the F.B.C. <br /> 18. "Green gypsum,board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. <br /> 19: Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. <br /> 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating <br /> - .. <br /> or appliances or an attached garage. They shall be installed in accordance with the F.B.C: <br /> 2_1. All plumbing,mechanical, and electrical shall be separate from unit to unit. This includes all <br /> underground plumbing and electric. <br /> 22. All 2016 N.E.C. Codes will be enforced. <br />