Laserfiche WebLink
23. Tamper- Resistant.Receptacles in accordance with 406.11 of the 2016 N.E:C <br /> 24. In accordance with the Land Development Code,lots.shall be sodded before final at least 10. <br /> feet around the structure. <br /> 26. R403.5.3Hot water pipe insulation. <br /> Insulation for_hot water. pipe with a minimum thermal resistance (R-value) of R-3 shall be applied to the <br /> following: <br /> Piping.V. inch (19.1 mm)and larger in.nominal,diameter.. <br /> Piping serving more than one dwelling unit. <br /> Piping located outside the conditioned space. <br /> Piping from the water heater to a distribution manifold., <br /> Piping.located under'a floor slab. <br /> Buried in piping, <br /> Supply and return piping in recirculation'systems other than demand recirculation systems. <br /> 25. Blower'door test shall be proviided before C.O. <br /> 26.A copy of the energy cacls shall be=with yerin t at all times <br /> 27. Com of final.irisulatio&-ieportshall be provided with permit before fnak <br /> 28 No fence,pool or screen enclosure :is issued with:this permit <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C-Florida Building Code 6t'Edition <br /> R.O.W.'-Right of Way <br /> A.D.A.=Americans with Disabilities Act N.E.C.-National Electric Code(2016) <br />