My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-461
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-461
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2022 7:14:13 AM
Creation date
3/4/2022 7:14:11 AM
Metadata
Fields
Template:
Building Department
Company Name
DR HORTON INC
Building Department - Doc Type
Permit
Permit #
20-461
Building Department - Name
DR HORTON INC
Address
7992 BROAD POINTE DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Q � <br /> � I 1 <br /> I <br /> t <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E. shall be.a minimum of 8" above the road elevation and an engineered site plan. <br /> 2. Lots shall be graded to'co ' ly with R401.3 of the F.B.C. <br /> 3. Compaction test required if 24"or more of fill dirt is brought in at any one place. <br /> 4. Tie in survey required before_pouring concrete. <br /> 5. Driveways require a R.O.W. use permit: .All 4 sides of driveway_ thrii the sidewalk shall have <br /> expansion material. <br /> 6. All setbacks shall be met. <br /> 7. All.property markers shall be uncovered-and marked at time of first inspection_ . <br /> 8. All A.D.A. requirements shall be met: . <br /> 9. No electric,plumbing;mechanical,or framing shall be covered without an inspection and <br /> approval first-. <br /> 10.. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation). <br /> 1.1. Appliances shall not be installed in a location where subject to mechanical.damage unless <br /> protected by approved barriers. M303:4 of the F.B:C <br /> 12. Water heaters shall comply with section P607.3 of the F.B.C. <br /> 13. Foundation supports for A/C-units shall be raised at least 3" above finished grade. M 1308:1 <br /> 14: Return air in all bedrooms. F.B.-C. M1620.4 <br /> 1.5. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C. <br /> 16:All glazing requirements are to be in accordance with R308.4 of the F.B.C: <br /> 17. All means of egress are to be in accordance with R311 of the F.B.C. <br /> 18. "Green gypsum board"shall riot be used as a backer in showers or tubs. R702.4.2 F.B.C. . <br /> 10. Combination-type AFCI.breakers are required at all locations requiring an AFCI type breaker. <br /> 20. Carbon monoxide alarms will be required iri new construction that uses fossil-burning heating <br /> or appliances or an attached garage. They shall be installed in accordance with the F.B.C. <br /> 21. All plumbing,mechanical,. and electrical shall be separate from unit to unit. This includes all <br /> -underground:plumbing and electric. <br /> 22. All 2016 N.E.C. Codes will be enforced. <br />
The URL can be used to link to this page
Your browser does not support the video tag.