Laserfiche WebLink
23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2016 N.E.0 <br /> 24. In accordance with the Land Development Code,lots shall.be sodded before final at least 10 <br /> feet around the structure. <br /> 25.-R403.5.3Hof water pipe insulation. <br /> Insulation for'hot Water pipe With'a minimum thermal resistance (R-value) of R-3 shall- be-applied to the <br /> followin <br /> Piping /<inch (19.1 mm)and larger in nominal diameter. <br /> Piping,serving more than.one dwelling unit. <br /> Piping located.outside the conditioned space.. <br /> Piping-from the water heater to a distribution manifold. <br /> .Piping.located under a floor slab.- <br /> Buried in piping, <br /> 'Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25:Blower door test shall be provided Before C.O: <br /> 26. A copy of the enemy cacls shall be with permit at all times. <br /> 27. Copy of final.insulation report shall be provided with perk:it before r1nat . <br /> 2.8. No fence,pool or screen enclosure :is issued with:this permit. <br /> F.F.E.-Finished Floor Elevation <br /> RB.C-.Florida Building Code 6a'Edition <br /> R.O.W:-Right of Way <br /> ' A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code (2016) <br />