My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-464
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-464
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2022 7:42:28 AM
Creation date
3/4/2022 7:42:27 AM
Metadata
Fields
Template:
Building Department
Company Name
DR HORTON INC
Building Department - Doc Type
Permit
Permit #
20-464
Building Department - Name
DR HORTON INC
Address
7980 BROAD POINTE DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
V, <br /> Q <br /> ti <br /> h <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E.. shall be a minimum of 8"above the road elevation and an engineered site plan. <br /> 2. Lots shall be graded to comply with R401.3 of the F.-B.C. <br /> 3. Compaction test required if 24"or more of fill dirt is brought in at any one place. <br /> 4. Tie in survey required before pouring concrete. <br /> .5-. .Driveways require a R.O.W. use permit. All 4 sides of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6: All setbacks shall be-met. <br /> 7. All.property markers shall be uncovered_ and marked at time of first inspection. <br /> & _All A-D:.A.requirements shall be met: . <br /> .9. No electric, plumbing; mechanical, or framing shall be:covered without an inspection and <br /> approval first. <br /> 10. All Garages,shall comply with section R302.6 of the F.B.,C. (Fire Separation). <br /> 11. Appliances shall not be installed in a location where subject to mechanical damage unless <br /> protected by approved barriers. M303A of the F.B.0 <br /> 12..Water heaters shall comply with section P607.3 of-the F.B.C.. <br /> 13. Foundation supports for A/C units shall be raised_ at least 3" above finished grade. M1308.1- <br /> 14. Return air in all bedrooms. F.B:C. M1620.4 <br /> 15. Smoke.detectors are to be installed in accordance with R3111 of the F.B.C. <br /> 16.All glazing requirements are to be in accordance with R308A of the F.B.C: <br /> 17. All means of egress are to be in accordance with R311 off the F.B.C. <br /> 18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 EB.C. <br /> 10. Combination-type AFCI breakers.are required at all locations requiring an AM.type breaker. <br /> 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating <br /> or appliances or an attached garage. They shall be installed in accordance with the F.B.C: <br /> 2.1. All plumbing,mechanical, and electrical shall be separate from unit to unit-. This includes all <br /> underground:plumbing and electric. <br /> 22: All 2016 N.E.C. Codes will be enforced. <br />
The URL can be used to link to this page
Your browser does not support the video tag.