Laserfiche WebLink
MIN.EMBEDMENT <br /> TYPICAL HEAD ANCHORAGE SEE TABLE 1 SUBSTRATE WIND VWND ilIlYl4 II\]r��/�I <br /> BY OTHERS OW SYSTEMS <br /> 1/4'MAX.SHIM SEE TABLE 1 MIN.EDGE DIST. SUBSTRATE 1900 SW 44TH AVE. <br /> MIN.EDGE DIST. SEE TABLE 1 BY OTHERS OCALA,FLORIDA 34474 <br /> SEE TABLE 1 VWWW.CWS.CC <br /> SUBSTRATE BY OTHERS SEE TABLE 1 1/4°MAX.SHIM MIN.EDGE DIST. <br /> SEE TABLE 1 SEE TABLE 1 <br /> MIN.EMBEDMENT 8300 PVC <br /> PERIMETER SEALANT SEE TABLE 1 INSTALLATION ANCHOR <br /> BY INSTALLER SEE TABLE 1 PICTURE WINDOW <br /> INSIDE AND OUT VB <br /> MIN.EMBEDMENT <br /> SEETABLEI NON-IMPACT <br /> SEALANT BEHIND n <br /> O O <br /> FLANGE BY INSTALLER Z < �1/4°MAX.SHIM �� < � �WOPERIMETER SEALANT Z W-ja <�ZWETER SEALANT BYINSTALLER W ZOZZTALLER INSIDE AND OUT 9 <to§Y O¢�m AND OUT INSTALLATION ANCHOR Z Z=2<¢W O Q <br /> ANT BEHIND SEE TABLE 1 0 O U)O U d Fx-co d <br /> FLANGE BY INSTALLER SEALANT BEHIND p Z-U)Z Z <br /> FIN BY INSTALLER Z Q 0 U C j O- <br /> INSTALLATION ANCHOR B HORIZONTAL SECTION C HORIZONTAL SECTION �-W�_O Z_ <br /> < Z OWO <br /> SEE TABLE 1 8 TYPICAL JAMB ANCHORAGE 8 TYPICAL FIN ANCHORAGE ¢ <Q O W H F Z <br /> HEAD AND SILL SIMILAR FOR FIN INSTALLATION F<- ¢O❑¢r}Z O� <br /> W W ¢U)Q WCOLU <br /> Fr Z!A W Q J!A F <br /> aco <br /> O WF--� W=¢>_ <br /> x <br /> ❑ D_ ~ n ¢ a <br /> 011101 <br /> 1/4°MAX SHIM �,�%%gP ORE vv p� <br /> SEALANT BEHIND YJ� ��Cb <br /> FLANGE BY INSTALLER O ;JGQ,�•V-� SF°';Q'G�, <br /> No 58201 '•11: <br /> PERIMETER SEALANT <br /> BYINSTALLER MIN.EMBEDMENT <br /> INSIDE AND OUT SEE TABLE �3% STATE OF F40 <br /> SUBSTRATE BY OTHERS NA�E����� <br /> SEE TABLE 1 MIN.EDGE DIST. <br /> SEE TABLE 1 <br /> SEALANT UNDER SCREW / n VERTICAL SECTION <br /> HEAD BY INSTALLER 8 TYPICAL SILL ANCHORAGE TCH <br /> 8/28/2017 <br /> TABLE 1:APPROVED INSTALLATION FASTENERS LUCAS A.TURNER,P.E. <br /> FRAME TYPE SUBSTRATE TYPE ANCHOR TYPE MIN.EMBEDMENT MIN.EDGE DIST. FL PE#58201 <br /> FLANGE CONCRETE(2.0 KSI MIN.) 3/16'ITW TAPCON 1-1/2' 1-1/8' 1239 JABARA AVE. <br /> PERIMETER SEALANT FLANGE HOLLOW OR GROUT-FILLED CMU(117 PCF MIN.) 3/16'ITN TAPCON i' 2° BY INSTALLER NORTH PORT,FL 34288 <br /> FLANGE CONCRETE(2.85 KSI MIN.) 3116'ELCO ULTRACON 1' 1' INSIDE AND OUT PH.941-380-1574 <br /> p HORIZONTAL SECTION SHEET DESCRIPTION: <br /> FLANGE GROUT-FILLED CMU(ASTM C-90) W16'ELCO ULTRACON 1-1/4' 2-1/2' 8 BOX FRAME INSTALLATION <br /> FLANGE 2X MIN.SOUTHERN PINE(G=0.55) 3/16'ITW TAPCON 1 3/8' 7/8• HEAD AND SILL SIMILAR FOR BOX INSTALLATION INSTALLATION DETAILS <br /> OR ELCO ULTRACON <br /> FLANGE 2X MIN.SOUTHERN PINE(G=0.55) #10 WOOD SCREW 1-3/8' 7/8' FLANGE REMOVAL NOTE:PARTIALLY OR FULLY REMOVING THE FLANGE, DRAWN BY: DATE: <br /> 16 GAUGE(0.060')MIN.STEEL STUD #10-16 HILT!KWIK-FLEX OR RW FULL THREAD UP TO AND INCLUDING A BOX-FRAME APPLICATION IS ACCEPTABLE PROVIDED: ADE 02/08/09 <br /> FLANGE (33 KSI YIELD MIN) TEKS SELF-DRILLING SCREW THRU 0.060' 7/16• DWG#: REV.: <br /> 1/8'ALUM. 6063-T5 MIN.)OR #10 GRADE 5 SELF-TAPPING/ FULL THREAD MIN. E FILLET, F FULL <br /> PERIMETER, ADE <br /> ADHESIVE CAULK IS APPLIED <br /> FLANGE ( 7/16• INSIDE AND OUT,FULL PERIMETER,BY INSTALLER. CWS-339 E <br /> 1/8'STEEL(33 KSI MIN.) DRILLING SCREW THRU 0.125' PRODUCT ANCHORAGE IS IN ACCORDANCE WITH REQUIREMENTS AS SCALE: SHEET <br /> FIN 2X MIN.SOUTHERN PINE(G=0.55) #10 WOOD SCREW 1-1/2' 1/2' SHOWN FOR FLANGE WINDOWS. 1:2 8 OF 8 <br />