Laserfiche WebLink
23, Tamper- Resistant.Receptacles in accordance with 406.11 of the 2016 N.E.0 <br /> .24. In accordance with the Land Development Code, lots shall.be sodded before final at least 10 <br /> feet around the structure. <br /> 25-. R403.5.3Hot water'pipe insulation <br /> Insulation for hot_Water pipe with a minimum thermal resistance (R-.value) of R-3 shall be applied to the <br /> following: . . . <br /> Piping 3h inch-(jq.1 mm)and larger-in nominal diameter. <br /> Piping serving more than one dwelling unit. <br /> Piping located.outside the conditioned space: <br /> Piping from the water heater to a distribution manifold-. <br /> Piping.located under a floor slab. <br /> Buried in piping, <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25.Blower door'test shall be provided before C.O: <br /> 26 A copy of the-energy:cacls shall be with permit at all times. <br /> gZ Copu of finalinsulation-retiort shaf-be provided ivith permit before&A <br /> 28.No fence,pool or'screen enclosure Is issued with Ais permit <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C-.Florida Building Code 6t'Edition <br /> R:O.W:-Right of Way <br /> A.D.A.=Americans with Disabilities-Act N.E.C.-National Electric Code(2016) <br />