Laserfiche WebLink
©- <br /> r <br /> i <br /> - 1 � <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. F:F.E;:shall be a minimum of 8" above the road elevation and an engineered site plan. <br /> 2. Lots shall be graded to comply with R401.3 of the F.B.C. <br /> 3. Compaction test required if 24"or more of fill dirt is brought in at any one place. <br /> 4: Tie m survey required before pouring concrete. <br /> .5. Driveways require.a R.O.W. use permit. All 4 sides of driveway_ thru the sidewalk shall have <br /> expansion material. <br /> 61 .All setbacks shall be met. <br /> 'T All property markers shall be uncovered and marked at time of first inspection. <br /> 8: All A.D.A.'requiremerits shall be,met: <br /> 9: No electric,.plumbing,mechanical, or framing shall be:covered without an inspection.and <br /> approval first. <br /> 10. All Garages_shall comply with section R3016' of the F.B.-C. (Fire Separation).: <br /> 11. Appliances shall not be 'installed in a location where subject to mechanical damage unless <br /> protected by:approved barriers. M303:4 of the F.B.0 <br /> 12.'Water heaters shall,comply with section P607.3 of the E.B.C. <br /> 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308:1 <br /> 14. Return air in all bedrooms. F.B.C. M1620.4 <br /> 15. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C. <br /> 16. All glazing requirements are to be in' accordance.:with R308.4 of the F:B:C. <br /> 17. All means of egress are to be in accordance with R311 of the F.B.C. <br /> 18. `-`Green gypsum board" shall not be used as a backer in showers or tubs. R702:4:2 F:B.C. . <br /> 10. Combination-type AFCI breakers are required at all locations requiring an AFCI.type breaker. <br /> 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating <br /> or appliances or an attached garage. They shall be installed in accordance with the-F.B.C: <br /> 21. All plumbing, inechanical, and electrical shall be separate from unit to unit. This includes all <br /> underground plumbing and.electric. <br /> 22. All 20T6 N:E.C. Codes will be enforced. <br />