ID . <br /> i <br /> Q� <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.RE;.shall be a minimum of 8" above the road elevation and an engineered site plan. <br /> 2' Lots slid 11 be graded to comply with R401:3 of the F.B.C. <br /> I. Compaction test required if 24"or more of fill dirt is brought in at any one place. <br /> .4. Tie in survey required-before pouring concrete. <br /> 5. Driveways require a R.O V. use permit: All 4 sides of driveway-thru the sidewalk shall have <br /> expansion material. <br /> 6. Al'! setbacks shall be met. <br /> 7. All,piroperty:markers shall be uncovered-and maiked at time of first inspection. <br /> & All A:D.A.requirements shall be met: <br /> 9: No electric,,plumbing.mechanical,or framing shall.be covered without an inspection and <br /> approval first. <br /> 10: All Garages shall comply with section R302.6 of the F.B:C. (Fire Separation). <br /> 11. Appliances shall.notbe installed in a location where subject.to mechanical-damage unless <br /> protected by'approved barriers. M303A of the F.B.0 <br /> 12..Water heaters shall comply with section P607.3 of the E.&C: <br /> 13. Foundation supports for A/C units,shall be raised at least 3" above finished grade. M1308:1 <br /> 14:.Return air in all bedrooms. F.B.C. M1620.4 <br /> 15. Smoke detectors are to be installed in accordance with R313:1 of.the F.B.C. <br /> 16: All glazing requirements are to be'in accordance with R308A of the ERE, <br /> 17. All means.of egress are to be in accordance with R311 of the R.B.C. <br /> 18. "Green gypsum board'.' shall not be used as a backer in showers or tubs. R702A.2 F.B.C. . <br /> 19: Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. <br /> 20. Carbon monoxide alarms will be required in new construction that.uses fossil-burning heating <br /> or appliances or an attached garage. They shall be installed in accordance.with the F.B.C. <br /> 21. All plumbing, mechanical, and electrical shall be separate from unit.to unit. This includes all <br /> underground plumbing and electric. <br /> 22. All 2016 ME.C. Codes will be enforced. <br />