Laserfiche WebLink
23. Tamper-Resistant Receptacles in accordance with 406.11 of the 2016 N.E.0 <br /> 24. In accordance with the Land Development Code, lots shall be sodded before final at least 10 <br /> feet around the structure. <br /> 25. R403.5.3Hot water.pipe insulation <br /> Insulation for hot water pipe with a minimum thermal resistance(R-.value) of R-3 shall be applied to the . <br /> following:.. <br /> Piping44 inch (19.1 mm)and larger.in nominal diameter.- <br /> Piping.serving more than:one dwelling unit. <br /> Piping located outside the conditioned space.. <br /> Piping from the water heater to a distribution manifold:. <br /> Piping:located under a floor slab. <br /> Buried in piping.. <br /> Supply and return piping iri recirculation systems other than demand recirculation systems. <br /> 25.Blower door test shall be provided before C,O: <br /> 26.A copy of the energy cacls shall be with permit at all tunes <br /> 27 Copy of final insulation report shall be provided with permit before final <br /> 28.No fence,pool or screen-enclosure :is issued with:thispermiz <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C-.:Florida Building Code 6t'Edition <br /> R.O.W.-Right of Way <br /> A.D.A.=.Americans with Disabilities Act N.E.C.-National Electric Code(2016) <br />