Laserfiche WebLink
D <br /> Q� <br /> t <br /> Single Family Dwelling <br /> Plan Review Comments . <br /> 1. F.F.E. shall.be a minimum of-8" above the road elevation and an engineered site plan. <br /> 2. Lots shall be graded to comply with R401.3 of the F:B.C: <br /> 3: Compaction test required.if 24" or more of fill dirt is brought in at any one place. <br /> 4: Tie in survey required before pouring concrete. <br /> 5. Driveways require.a R.O.W.use permit: All sides of driveway thru the sidewalk shall have <br /> expansion material. <br /> & All setbacks-shall be met. <br /> 7: All property markers shall be uncovered'and marked at time of first inspection. <br /> K All A.D.A.-requirements shall be met: <br /> 9. No electric,.plumbing;mechanical, or framing shall.be:covered without an inspection and <br /> approval first. <br /> 10. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation). <br /> . <br /> 11. Appliances shall.not be-installed installed in a location where subject to mechanical.damage unless <br /> protected by approved barriers. M303.A of the RB.0 <br /> 12. Water heaters shall comply with section P607.3 of the F.B.C. <br /> 13. Foundation supports for A/C units.shall be raised at least 3"-above finished grade. M1308A <br /> . 14. Retuai air in all bedrooms. F.B.C. M1620:4 <br /> 1.5. Smoke detectors are to be.installed in accordance with R313.1 of the' F.B.0 <br /> 16. All glazing requirements are to be:in accordance with R308.4 of the F.&C. <br /> 17. All means of egress are to be in accordance with R311 of the F.B.C. <br /> 18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. <br /> 196 Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker <br /> 20. Carbon monoxide alarms will be required in new construction that-uses fossil-burning heating <br /> or appliances or an attached garage. They shall be installed in accordance with the F.B.C. <br /> 21. All plumbing,mechanical; and electrical shall be separate from unit to unit. This includes all <br /> underground plumbing and electric. <br /> 21 All 2U6 N.-E.C. Codes will be enforced: <br />