Laserfiche WebLink
23. 'Tamper- Resistant.Receptacles in accordance with 406.11 6fthe 2016 N.E.0 <br /> 24. In accordance with the Land Develop_merit Code, lots shall be-sodded before final at least 10 <br /> feet around the structure. <br /> 25: R403.5.3Hot.waterpipe insulation. <br /> Insulation for_hot.water. pipe with a minimum thermal resistance (R-value) of R-3 shall.be applied.to the <br /> following: <br /> Piping 314 inch (1,9.1 mm) and larger .in.nominal diameter._ <br /> Piping serving more than.one dwelling unit. <br /> Piping located outside the conditioned space. <br /> Piping from the:water-heater to:a:distribution manifold:. <br /> Piping located under a floor slab. <br /> Buried in piping.. <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25.Blower'door test shall be provided before C,O. <br /> 26.A cony 0the energy cacls shall be with permit at all times <br /> 27., Copy of Thal insulation report shall be provided with permit before final <br /> 28:No fence, pool or screen enclosure :is issued with this,vermin' <br /> RRE.-Finished Floor Elevation <br /> RB.C-.Florida Building Code 6th Edition <br /> R.O.W.-Right of Way <br /> A.D.A. Americans with Disabilities Act. N.E.C.-National Electric Code (2016) . <br />