Laserfiche WebLink
23. Tamper- Resistant.Receptacles in accordance with 406.11 of the 2016 N.E.0 <br /> 24. In accordance with the Land Development Code,lots-shall be-sodded before foul at least 10 <br /> feet around the structure. <br /> 25. R403.5.3Hot.water,pipe insulation <br /> Insulation for hot.water- pipe with a minimum thermal resistance (R-value) of R-3 shall be applied to the <br /> following: <br /> Piping-3/, inch (19:1.mm) and larger in.:nominal diameter.. <br /> Piping serving more than:one dwelling unit. <br /> Piping located outside the conditioned space... <br /> Piping from the water heater to a distribution manifold:. <br /> piping.located under a floor slab.. <br /> Buried in piping. <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25. Blower:door test shall be pricMded:before C.O: <br /> 26. A copy of the enerzy cacls shall be with permit at all times <br /> Z.Copy of final insulation report shall be provided ivith permit before final <br /> 28:No-fence,pool or screen enclosure :is issued with:this permit <br /> F.F:E.-Finished Floor Elevation <br /> F.B.C-..Florida Building Code 6t'Edition <br /> R.O.W.-Right of Way <br /> A.D.A.=.Americans with Disabilities Act N.E.C.-National Electric.Code(2016) <br />