A & It Gulf <br /> SUPPLY & MANUFACTURING <br /> C o 9s t <br /> TM <br /> GULFR � DDD <br /> 29 GUAGE GULFRIB" PANEL OVER 1X4 WOOD PURLINS OVER 15/32" PLYWOOD <br /> -ORIDA PRODUCT APPROVAL NO. 11651.25 R3 <br /> "IF I iV' <br /> ENGINEER LOAD TABLE:29 Ga.GulfRibTM Panel over 1x4 Wood Purlins over 15/32"Plywood <br /> d <br /> h <br /> '-C <br /> 120 130 140 150 160 170 180 <br /> WIIND FASTENER <br /> SPEED (MIN.1/4" SUBSTRATE ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER <br /> Penetration) SPACING SPACING SPACING SPACING SPACING SPACING SPACING <br /> 0 <br /> PE-11' <br /> F TYPE: IN <br /> ZONE 2 #9-115x'11.5.1 1x4 Wood 24",TYPE 1 24",TYPE 1 24",TYPE 1 24!,TYPE 1 24",TYPE 1 24!,TYPE 1 24,TYPE I <br /> Purlins <br /> -4v <br /> PE'4';;'-24r-.-�TYPEA flV.-TY <br /> E <br /> 1.)PANEL DESCRIPTION:GULFRIBTM,MIN.29 GA.,GRADE 98,36"COVERAGE,3/4"TALL. <br /> 2.)PANEL FASTENER:#9-1 SX1.5" HWH WITH SEALING WASHER OR APPROVED EQUAL <br /> 3.)MAXIMUM ALLOWABLE PANEL UPLIFT PRESSURE:76.75 PSF @ 24"O.C.FASTENER SPACING TYPE 1 FASTENER PATTERN, 123.5 <br /> PSF @ 24" O.C. FASTENER SPACING TYPE 2 FASTENER PATTERN BASED ON TAS 125, UL 580/UL 1897 TESTING. <br /> 4.)SUBSTRATE: 1X4 WOOD PURLINS OVER MIN.IsIn"THICK PLYWOOD.WOOD PURLINS ATTACHED TO PLYWOOD W/MIN.8D X <br /> 21/2" RING SHANK NAILS AT 4" O.C.PURLINS AND PLYWOOD MUST BE DESIGNED IN ACCORDANCE WITH FBC 2017 <br /> 5.)ROOF SLOPE:ON ROOF SLOPES LESS THAN 3:12,LAP SEALANT MUST BE USED IN PANEL SIDE LAPS, <br /> 6.)LOAD TABLE BASED ON WIND PRESSURES CALCULATED PER ASCE 7-10(KD=0.85)MULTIPLIED BY 0.6 PER FLORIDA BUILDING <br /> CODE 2017. <br /> ZONE 2 HIP—ROOF a Note:Dimension(a)is defined as 10%of the minimum width of the building or <br /> ZONE 3-,,,, <br /> 40%of the mean height of the roof,whichever is smaller,however,(a)cannot be <br /> less than either 4%of the minimum width of the building or 3 feet <br /> RIDGE TYPE 1 FASTENER PATTERN <br /> x 4 Wood Purlins Q 24"O.C.Attached to Plywood with <br /> (1)Od x 2.5"Ring Shank Nails 9 4"O.C. At Panel Lap <br /> T 911 <br /> ZONE1 <br /> /----- ------- <br /> (1)#9-15 x 1-1/2vdSealer Washer Min.15132"Plywood <br /> EAVE 9-9*-9-W Fastener Pattern 0 24"O.C. <br /> ZONE GABLE ROOF <br /> 1-1\ I'll TYPE 2 FASTENER PATTERN <br /> -j-\------------------ —1a <br /> x 4 Wood Purlins g 12"O.C.Attached to Plywood with <br /> (1)8d x 2.5'Ring Shank Nails g 4"D.C. <br /> -RIDGE 6.51- If 2.511-r <br /> ---------------------- <br /> ZONE i L(1)#9-15 x 1-1/2"w/Seater Washer Min.15/32Plywood <br /> 6.5"-2.5-6.5"-2.5"-6.5"-2.5'�-6.5"Fastener Pattern 0 24"O.C. <br /> -------------------4- <br /> �ZONE 3 \-EAVE <br /> FL#11651.25 R3 a OCTOBER 5,2017 <br /> F A <br /> _� KUHN ENGINEERING, LLC <br /> 1200 CLI.N;T MO ORE RD. SUITE 9. BOCA RATON. I"L 33487 - FL COA-'00464 <br />