My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-580
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-580
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/7/2022 2:11:45 PM
Creation date
3/4/2022 8:57:50 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
20-580
Building Department - Name
KNAPP,ROSEMARIE
Address
4625 EAGLE RANCH DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DocuSign Envelope ID:BB72B374-2663-40C9-9881-C4A388601545 <br /> 3. The following mounting types shall be used. Please refer to the mounting details for the associated mounting <br /> method requirements. Based on our evaluation, the uplift demand is less than the maximum allowable per <br /> mount and therefore is adequate. <br /> • Rock-It: (1) 5/16" lag screw. Pullout capacity based on National Design Specifications (NDS) of timber <br /> construction specifications for Southern Pine is 235 Ibs/inch penetration. <br /> 4. Fasteners are installed to meet industry standards and this document satisfies requirements in 2017 FBC <br /> 2303.4.5 verifying that the fasteners will not adversely affect the roof framing. <br /> 5. The maximum allowed spacing was calculated for the Wind Speed shown in paragraph B above, using the wind <br /> load uplift procedures of ASCE 7-10. These spacing requirements apply to all mount types indicated above. <br /> The following values have been verified by in-house testing and the mounting hardware manufacturers' data, <br /> which are available upon request. Panel support connections should be staggered,where possible,to distribute <br /> load to adjacent members. <br /> Modules in Landscape Modules in Portrait <br /> Roof Zone Interior Ede Corner Interior Ede Corner <br /> Max Vertical Spacing in 40 40 40 66 66 66 <br /> Max Horizontal Spacing in 48 48 48 48 48 48 <br /> Max Uplift Load Ibs 341 273 253 573 229 106 <br /> D. Summary <br /> Based on the above evaluation, with appropriate panel anchors being utilized, the roof system designed on will <br /> adequately support the additional loading imposed by the solar panels, if installed correctly. This evaluation has <br /> been performed for the structural elements only and verifies that they are in conformance with the 2017 Florida <br /> Building Code-Residential 6th Edition, current industry standards and practice, and the information supplied to us <br /> at the time of this report. <br /> If there are any questions regarding the above, or if more information is required, please contact me. <br /> Regards, \\ P'i,(HEw <br /> J. Matthew Walsh, PE <br /> FL License No. 84923 * N, 84y'� ; <br /> p STATE OF ; <br /> DocuSigned by: j 0'.� <br /> E -%ssoNAL �� ..�. <br /> 7AEED20514FE4D2. �� 111111``\�� <br /> Matt Walsh <br /> 08/10/2020 <br /> This item has been electronically signed and sealed by <br /> Matt Walsh using a Digital Signature and date.Printed <br /> copies of this document are not considered signed <br /> and sealed and the signature must be verified on any <br /> electronic copies. <br /> Page 2 of 2 vivi nt• s o I a r <br />
The URL can be used to link to this page
Your browser does not support the video tag.