My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
21-1308
Zephyrhills
>
Building Department
>
Permits
>
2021
>
21-1308
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/9/2022 1:36:15 PM
Creation date
5/6/2022 1:10:54 PM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
21-1308
Building Department - Name
OLIVERA,JORGE & DAISY
Address
39155 11TH AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Enphase IQ 7 and IQ 7+ Microinverters <br /> INPUT DATA(DC) IQ7-60-2-US IQ7PLUS-72-2-US <br /> Commonly used module pairings_' 235 W-350 W+ 235 W-440 W+ <br /> Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules <br /> Maximum input DC voltage 48 V 60 V <br /> Peak powertracking voltage 27 V 37 V 27 V 45 V <br /> Operating range 16 V-48 V 16 V-60 V <br /> Min/Max start voltage 22 V/48 V 22 V/60 V <br /> Max DC short circuit current(mod_u_le Ise)_ 15 A 15 A <br /> Overvoltage class DC port II II <br /> ----- - --- - -- ---- - - -- - , <br /> DC port backfeed current 0 A 0 A <br /> PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; <br /> AC side protection requires max 20A per branch circuit <br /> OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter <br /> _Peak output power 250 VA 295 VA <br /> Maximum continuous output power 240 VA 290 VA <br /> Nominal(L-L)voltage/range2 240 V/ 208 V/ 240 V/ 208 V/ <br /> 211-264 V 183-229 V 211-264 V 183-229 V <br /> Maximum continuous output current 1.0 A(240 V) 1.15 A(208 V) 1.21 A(240 V) 1.39 A(208 V) <br /> Nominal frequency 60 Hz 60 Hz <br /> Extended frequency range 47-68 Hz 47-68 Hz <br /> AC short circuit fault current over 3 -cycles- 5.8 Arms 5.8 Arms <br /> Maximum units per 20 A(L-L)branch circuit' 16(240 VAC) 13(208 VAC) 13(240 VAC) 11 (208 VAC) <br /> _Overvoltage class AC port III I I I <br /> AC port backfeed current 18 mA 18 mA <br /> Power factor setting 1.0 1.0 <br /> Power factor(adjustable) 0.85 leading...0.85 lagging 0.85 leading...0.85 lagging <br /> EFFICIENCY @240 V @208 V @240 V @208 V <br /> Peak efficiency 97.6% 97.6% 97.5% 97.3% <br /> CEC weighted efficiency 97.0% 97.0% 97.0% 97.0% <br /> MECHANICAL DATA <br /> Ambient temperature range -400C to+65°C <br /> Relative humidity range 4%to 100%(condensing) <br /> Connectortype MC4(or Amphenol H4 UTX with additional Q-DCC-5 adapter) <br /> Dimensions(HxWxD) 212 mm x 175 mm x 30.2 mm(without bracket) <br /> Weight 1.08 kg(2.38 Ibs) <br /> Cooling Natural convection-No fans <br /> Approved for wet locations Yes <br /> Pollution degree PD3 <br /> Enclosure Class II double-insulated,corrosion resistant polymeric enclosure <br /> Environmental category/UV exposure rating NEMA Type 6/outdoor <br /> FEATURES <br /> Communication Power Line Communication(PLC) <br /> Monitoring Enlighten Manager and MyEnlighten monitoring options. <br /> Both options require installation of an Enphase IQ Envoy. <br /> Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break <br /> disconnect required by NEC 690. <br /> Compliance CA Rule 21 (UL 1741-SA) <br /> UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, <br /> CAN/CSA-C22.2 NO.107.1-01 <br /> This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and <br /> NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC <br /> and DC conductors,when installed according manufacturer's instructions. <br /> 1.No enforced DC/AC ratio-See the compatibility calculator at httos•//enphase com/en-us/support/module-compatibility. <br /> 2.Nominal voltage range can be extended beyond nominal if required by the utility. <br /> 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. <br /> To learn more about Enphase offerings,visit enphase.com u E N P H AS E. <br /> 2020 Enphase Energy.All rights reserved.Enphase,the Enphase logo,Enphase IQ 7,Enphase IQ 7+,Enphase IQ Battery, <br /> Enphase Enlighten,Enphase IQ Envoy,and other trademarks or service names are the trademarks of Enphase Energy,Inc.Data subject to change.2020-01-06 <br />
The URL can be used to link to this page
Your browser does not support the video tag.