Product Approval Method Method 1 Option D
<br /> Date Submitted 06/18/2018
<br /> Date Validated 06/20/2018
<br /> Date Pending FBC Approval 66/26/2018
<br /> Date Approved 08/15/2018
<br /> Date Revised 04/06/2020
<br /> Summary of Products
<br /> Go to Page Page 1/2
<br /> FL# Model,Number or Name Description
<br /> 15012.1 kfL; 2140,2141,2240,2241,2150, 06'-00"to 09'-00"wide by 20'high steel sectional door with
<br /> 2151,,2250,2251,2550,2551, or without polystyrene insulation.
<br /> 4140,4141,4240,4241,4150,
<br /> 4151,4250,4251,5240,5241,
<br /> 5250;5251,5940,5941,5950,
<br /> 5951'
<br /> Limits of Use Installation Instructions
<br /> Approved for use in HVHZ:No FL15012 R6 II lamb Attachment Drawings s Ddf
<br /> Approved for use outside HVHZ:Yes F1_15012.R6 II Z4-09-013L6 s.Ddf
<br /> Impact Resistant:No Verified By:John E.Scates,PE FL-51737
<br /> Design Pressure: N/A Created by Independent Third Party:Yes
<br /> Other:Sectional doors provided for windload applications Evaluation Reports
<br /> and have been tested in accordance with ASTM E330 and FL15612 R6 AE FL15012 Eval Reot Dan.r6 s.Ddf
<br /> ANSI/DASMA 108,Z4-09-013L6 Residential Pan 09'-00"wide Created'by Independent Third Party;Yes
<br /> @+23.2/-26.2 PSF,see drawing for additional widths and
<br /> pressures.
<br /> 15012.2 kgL; 2140,2141,2240,2241, 06-00"to 10'-00"wide by 20'high steel sectional door with
<br /> 2150,2151,2250,2251,2550, or without polystyrene insulation.
<br /> 2551,4140,4141,4240,4241,
<br /> 4150,4151,4250,4251,5240,
<br /> 5241,5250,5251,5940,5941,
<br /> 5950,5951
<br /> Limits of Use Installation Instructions
<br /> Approved for use in HVHZ:No FL15012 R6 II Jamb Attachment Drawings s.Ddf
<br /> Approved for use outside HVHZ:Yes FL15012 R6 II Z5-09-0131_6 s.Ddf
<br /> Impact Resistant:No Verified By:John E.Scates,P.E.FL-51737
<br /> Design Pressure: N/A Created by Independent Third Party:Yes
<br /> Other:Sectional doors provided for windload applications Evaluation Reports
<br /> and have been tested in accordance with ASTM E330 and FL15012 R6 AE FL15012 Eval'Reot Dan r6 s.Ddf
<br /> ANSI/DASMA 108.ZS-09-013L6 Residential Pan 09'-00"wide Create_d by Independent Third Party:Yes
<br /> @+27.3/-30.8 PSF,see drawing for additional widths and
<br /> pressures.
<br /> 15012.3 khI;2140,2141,2240,2241, 09'-00"to 06-00"wide by 20'high steel sectional door with
<br /> 2150,2151,2250,2251,2550, or without polystyrene insulation.
<br /> 2551,4140,4141,4240;4241,
<br /> 4150,4151,4250,4251,5240,
<br /> 5241,5250,5251,5940,5941,
<br /> 5950,5951
<br /> Limits of Use Installation Instructions
<br /> Approved for use in HVHZ:No FL15012 R6 II Jamb Attachment.Drawings s.Ddf
<br /> Approved for use outside HVHZ:Yes FL15012 R6 II Z6i-09-01507 s.Ddf
<br /> Impact Resistant:Yes Verified By:John E.Scates,P.E.FL-51737
<br /> Design Pressure: N/A Created by Independent Third Party:Yes
<br /> Other:Sectional doors provided for potential"code-plus" Evaluation Reports
<br /> applications. Large Missile impact(9 pound missile)and FL15012 R6 AE FL15012 Eval Regt Dan r6 s.Ddf
<br /> cycling tests conducted in accordance with ANSI/DASMA 115. Created by Independent Third Party:Yes
<br /> Static tests conducted in accordance with ASTM E330 and
<br /> ANSI/DASMA 108.Z6i-09-01507 Residential Pan 09'-00"
<br /> wide @+32.0/-36.2 PSF,see drawing for additional widths
<br /> and pressures.
<br /> 15012.4 kiL; 2140,2141,2240,2241,2150, 06-00"to 09'-00"wide by 20'high steel sectional door with
<br /> 2151,2250,2251,2550,2551, or without polystyrene insulation.
<br /> 4140,4141,4240,4241,4150,
<br /> 4151,4250,4251,5240, 5241,
<br /> 5250, 5251,5940,5941,5950,
<br /> 5951
<br /> Limits of Use Installation Instructions
<br /> Approved for use in HVHZ:No FL15012 R6 II Jamb Attachment Drawings s Ddf
<br /> Approved for use outside HVHZ:Yes FL15012 R6 II Z7-09-013L6 s.odf'
<br />
|