21 Tamper- Resistant Receptacles in accordance with 406.11 of the 2016 N.E.0 <br /> 24. In accordance with the Land Development Code,lots shall be sodded before final at least.10 <br /> feet around the structure. <br /> 25. R403.5.3Hot water pipe insulation <br /> insulation for hot water pipe with a minimum thermal resistance (R-value) of R-3 shall.be applied to the . <br /> following: <br /> Piping 3/;inch (19.1 mm) and larger in nominal diame_ter. <br /> Piping:serving more than.one dwelling unit. <br /> Piping located outside the conditioned space._ <br /> Piping from the water heater to a distribution manifold. <br /> Piping:located under a floor slab. j <br /> Buried in piping. <br /> Supply and return piping in recirculation systems oth Ir than demand recirculation systems. <br /> 25. Blower door'test shall be provided before C.O: <br /> 26.A copy of the merry.cacls shall be with permit at all times- <br /> 27. Copy of final.insulddon report shall be provided iuith permit before final <br /> 28.No fence,Pool or'scre-en enclosure :is issued with:this-permit: <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C- Florida Building Code 6t'Edition <br /> R.O.W.-Right of Way j <br /> A.D.A.=Americans with Disabilities Act_ N.E.C.-National Electric.Code (2016) <br /> i <br /> i <br /> i <br /> I <br /> i <br />