Laserfiche WebLink
STATE COPY <br /> FORM R405-2020 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: KH02127 Palmera(TAM) Builder Name: K Hovnanian Homes <br /> Street: 6834 Shelby Lynn Way Permit Office: City of Zephyrhills <br /> City,State,Zip: Zephyrhills,FL, Permit Number: <br /> Owner: Jurisdiction: <br /> Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) <br /> 1. New construction or eAstirig New(From Plans) 10. Wall Type$1907.4 sgft.) Insulation Area <br /> 2. Single family or multiple family Detached a.Concrete Block-Int Insul,Exterior R=4.1 1635.80 ft2 <br /> b.Frame-Wood,Adjacent R=11.0 271.56 ft2 <br /> 3. Number of units,if multiple family 1 c.NIA R= ft2 <br /> 4. Number of Bedrooms 4 d.N/A R= ft2 <br /> 5. Is this a worst case? Yes 11.Ceiling Types (2127.0 sgft.) Insulation Area a.Under Attic(Vented) R=30.0 2127.00 ft2 <br /> 6. Conditioned floor area above grade(112) 2127 b.NIA R= ft2 <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 <br /> 7. Windows(174.3 sgft.) Description Area 12.Ducts R ft2 <br /> a. U-Factor: Dbl,U=0.34 118.12 ft2 a.Sup:Attic,Ret:Main,AH:Main 6 273 <br /> SHGC: SHGC=0.23 <br /> b. U-Factor: Dbl,U=0.63 40.00 ft2 13.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 33.1 SEER:15.00 <br /> c. U-Factor. Dbl,U=0.34 16.19 ft2 <br /> SHGC: SHGC=0.29 14.Heating systems kBtu/hr Efficiency <br /> Area Weighted Average Overhang Depth: 4.634 ft. a.Electric Heat Pump 32.6 HSPF:8.50 <br /> Area Weighted Average SHGC: 0.256 <br /> 8. Skylights Area <br /> c. U-Factor.(AVG) N/A ft2 15.Hot water systems <br /> SHGC(AVG): N/A a.Electric Cap:50 gallons <br /> 9. Floor Types (2127.0 sgft.) Insulation Area EF:0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 2127.00 ft2 b. Conservation features <br /> b.N/A R= ft2 None <br /> C.N/A R= ft2 16.Credits Pstat <br /> Glass/Floor Area: 0.082 Total Proposed Modified Loads: 61.61 PASS <br /> Total Baseline Loads: 62.12 <br /> I hereby certify that the plans and specifications covered by Review of the plans and O j-T STg?,. <br /> this calculation are in compliance with the Florida Energy specifications covered by this y� _ 0� <br /> Code. calculation indicates compliance � <br /> with the Florida Energy Code. `�O <br /> PREPARED BY: �/�/�/P-� Before construction is completed <br /> DATE: 1-13-20 this building will be inspected for `';i` <br /> compliance with Section 553.908 t ` ° <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. <br /> with the Florida Energy Code. cDD WE'T�� <br /> OWNER/AGENT: BUILDING OFFICIAL: <br /> DATE: 1/1 312 02 1 DATE: <br /> - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.3.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an <br /> envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). <br /> l <br /> 1/12/2021 11:58 AM 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 4 <br />