Laserfiche WebLink
ROMFL12231-R5 <br /> Installation Instructions: Attachment Details <br /> Table 1:Allowable Pressures <br /> Allowable Pressure"(psf) <br /> Typical Nails3 Staples3 <br /> Additional Product Thickness. <br /> Product'Name Names Profile (in.) 16"oc. 8"oc 16"oc 8"oc <br /> D4,.DL4 87 123 56 --- <br /> Fairfield Alpine Ridge 0.044 <br /> D5, DL5 43 88 43 --- <br /> D4,.DL4.5, D5, 71 <br /> Spiegel Grove Addison Heights DL5,T3.33 0.040 58 125 1194 -- <br /> D4 87 123 56 --- <br /> Oak Harbor Bristol Bay 0.042 <br /> DL4.5, D5, DL5 43 . 88 43 -- <br /> Pro Pride -- 131-4.5 0.038 53 100 47 111 <br /> 514 <br /> Carrington Collection -- D4,-DL4.5 0.046 565 5 -- 71 --- <br /> 6.5 Beaded -- Beaded 6.5 0.044 45 --- --- -- <br /> Board and Batten -- Board and Batten 7 0.048 65 when nailed_at --- -- <br /> 12"oc into 7/16 OSB <br /> I Allowable pressure determined in accordance with ASTM D3679-17,calculated using the following equation: <br /> Dr =Pe/(0.5 x 1.5), <br /> where Pt is the average maximum sustained static test pressure. <br /> 2 Allowable pressure applies to the siding only.The strength of the structural sheathing,framing,and the `�`®�� �ce�s•�C�'®® <br /> withdrawal strength of the specified connectors in the structural framing must be designed in accordance <br /> with accepted engineering practice by a registered design professional. o. 57 <br /> 3 Refer to Section 5.4 for fastener requirements and referenced test reports for additional details of installation. <br /> °The second_value is for Double Stapled at 16"oc. s _ <br /> 5 The first value is for installation through the top nail slot of the double hem',the second value is for installation ®� <br /> through the bottom. ®t, . STD t JF ,�® <br /> 10/7/2020 <br />