Laserfiche WebLink
I <br /> / Single Phase Inverter <br /> I , <br /> With HD-Wave Technology for North America <br /> SE3000H-US / SE380OH-US % SE5000H SUS / SE6000H-US/ <br /> SE760OH-US / SE1000OH-US / SE114001H-US <br /> OUTPUT <br /> 3800 @ 240V 6000 @ 240V 11400 @ 240V <br /> Rated AC Power Output 3000 3300 @ 208V 5000 5000 @ 208V 7600 10000 10000 @ 208V VA <br /> Maximum AC Power Output 3000 3800 @ 240V 5600 6000 @ 240V 7600 10000 11400 @ 240V VA <br /> 3300 @ 208V 5000 @ 208V 10000_@ 208V <br /> AC Output Voltage Min.-Nom.-Max. ✓ ✓ ✓ ✓ ✓ ✓ ✓ Vac <br /> (211-240-264) <br /> AC Output Voltage Min.-Nom.-Max. ✓ ✓ ✓ Vac <br /> (183-208-229) <br /> AC Frequency(Nominal) 59.3-60-60.511) Hz <br /> Maximum Continuous Output 12.5 16 21 25 32 42 I 47.5 A <br /> Current @240V <br /> Maximum Continuous Output - 16 - 24 - 48.5 A <br /> Current @208V. <br /> GFDI Threshold I 1 A <br /> Utility Monitoring,Islanding Protection, <br /> Country Configurable Thresholds Yes <br /> INPUT j <br /> Maximum DC Power @240V 4650 5900 7750 9300 11800 1 15500 17650 W <br /> Maximum DC Power @208V - 5100 - I 7750 15500 W <br /> Transformer-less,Ungrounded Yes <br /> Maximum Input Voltage 480 Vdc <br /> Nominal DC Input Voltage 380 400 Vdc <br /> Maximum Input Current @240V111 8.5 10.5 13.5 16.5 20 27 30.5 Adc <br /> Maximum Input Current @208V(I) - 9 13.5 - I 27 Adc <br /> Max.Input Short Circuit Current 45 Adc <br /> Reverse-Polarity Protection Yes <br /> Ground-Fault Isolation Detection I 600ko Sensitivity <br /> Maximum Inverter Efficiency 99 99.2 % <br /> CEC Weighted Efficiency pg 99 @ 240V <br /> 98.5 @ 208V <br /> Nighttime Power Consumption I <2.5 W <br /> ADDITIONAL FEATURES <br /> Supported Communication Interfaces j RS485,Ethernet,ZigBee(optional),Cellular(optional) <br /> Revenue Grade Data,ANSI C12.20 Optionall") <br /> Rapid Shutdown NEC 2014 and Automatic Rapid Shutdown upon AC Grid Disconnect <br /> 2017 690.12 <br /> STANDARD COMPLIANCE <br /> Safety UL1741,UL1741 SA,UL1699B,CSA C222,Canadian AFCI according to T.I.L.M-07 <br /> Grid Connection Standards IEEE1547,Rule 21,Rule 14(HI) <br /> Emissions FCC Part 15 Class B <br /> INSTALLATION SPECIFICATIONS j <br /> AC Output Conduit Size/AWG Range 1"Maximum/14-6 AWG 1"Maximum/14-4 AWG <br /> DC Input Conduit Size/#of Strings/ 1,"Maximum/1-2 strings/i4-6 AWG 1"Maximum/1-3 strings/14-6 AWG <br /> AWG Range <br /> (Dimensions <br /> mensi ns with Safety Switch 17.7 x 14.6 x 6.8 /450 x 31 0 x 174 21.3 x 14.6 x 7.3/540 x 370 x 185 in <br /> Weight with Safety Switch 22110 25.1/11.4 26.2/11.9 38.8/17.6 lb/kg <br /> Noise <25 I <50 dBA <br /> Cooling Natural Convection <br /> Operating Temperature Range -13 to+140/-25 to+6011)(-40'F/-40°C option)15' °F/°C <br /> Protection Rating NEM 4X(Inverter with Safety Switch) <br /> nl For other regional settings please contact SolarEdge support <br /> a,A higher current source may be used;the inverter will limit its input current to the values stated <br /> *Revenue grade inverter P/N:SExxxxH-USOOONNC2 <br /> *For power de-rating information refer to;httpsY/www.solaredge.com/sites/default/files/se-temperature-derating-note-na pdf <br /> `s'-40 version P/N:SEroowH-USOOON1,11.14 <br /> ®SolarEdge Technologies,Inc All rights reserved.SOLAREDGE,the SolarEdge logo,OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies,Inc All Rn H S <br />