Laserfiche WebLink
D <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E;.shall be a minimum of 8" above the road elevation and an engineered site plan. <br /> 2: Lots shall be graded to comply with R401.3:of the F.B.C.- <br /> Compaction test required if 24"or more of fill dirt is brought in at any one.place. <br /> 4: Tie in survey required before pouring concrete. <br /> 5. Driveways require a R.O.W. use permit: All 4 sides of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6: All setbacks shall be met. <br /> 7: All property markers sliall be uncovered and marked at time of first inspection. <br /> 8: All A.D.A. requirements shall be met: <br /> 9: No electric,.plumbing, mechanical, or framing shall be- covered without an inspection and <br /> approval first. <br /> 10. All Garages shall comply with section R30.16 of the F.B.C. (Fite Separation): <br /> 11. Appliances shall not be installed in a location where subject to mechanical damage unless <br /> protected by approved barriers. M303.4 of the F B.0 <br /> 12. Water heaters shall comply with section P607.3 of the F.B:C. <br /> 13. Foundation supports for A/C units shall b:e.raised at least 3" above Anislied grade. M1308A. . <br /> 14. Return air in all bedrooms. F.B.-C. M1620.4 <br /> 15. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C. <br /> 16. All glazing requirements are to be in accordance with R308.4 of the F.B.C. <br /> 17. All means of egress are to be in.accordance'with R311 ofF.B.C.the F. <br /> 18. "Green gypsum board" shall riot be used as a backer in showers or tubs: R702.4.2 F.B.C. <br /> 10. Combination-type AFCI breakers are required at all locations requiring an AFCI.type breaker. <br /> 20. Carbon monoxide alarms will be'required iri new construction that uses fossil-burning Beating <br /> or appliances or an attached garage. They shall be installed in accordance with the F.B.C: <br /> 21. All plumbing,mechanical, and electrical shall b.e separate from unit to unit. This includes all <br /> underground plumbing and electric. <br /> M All 2016 N.E.C. Codes will be enforced. <br />