My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
21-1382
Zephyrhills
>
Building Department
>
Permits
>
2021
>
21-1382
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/9/2022 1:59:12 PM
Creation date
5/9/2022 7:00:59 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
21-1382
Building Department - Name
CARR,LUCETTE
Address
6025 11TH ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GODWIN ENGINEERING AND DESIGN, LLC <br /> 8378 Foxtail Loop,Pensacola, FL 32526 1 (850)712-4219 I Iliad godwineng.com <br /> January 12, 2021 <br /> To: Zephyrhills Building Department <br /> 5335 8th St. <br /> Zephyrhills, FL 33542 <br /> Re: Carr-Residential PV Roof Mount Installation <br /> 6025 11th St. <br /> Zephyrhills,FL 33542 <br /> Plan Reviewer, <br /> This letter is regarding the installation of a new roof mounted Solar PV System on the existing <br /> residential structure at the address above. I have reviewed the attachment plan and have <br /> determined that the roof mounted PV system is in compliance with the applicable sections of the <br /> following Codes as amended and adopted by the jurisdiction: <br /> 2020 Florida Building Code 7th Edition,FBC <br /> ASCE 7 Min.Design Loads for Buildings&Other Structures <br /> Per 2020 FBC,the Roof Mounted PV system will be subject to the following design criteria: <br /> Design Wind Speed(V„lt) - 140mph 3sec gust,Exposure Category-B <br /> The PV System consist of the modules,railing,and connection hardware.The system will add a <br /> dead load of approximately 3 psf to the roof. <br /> The existing roof covering is Asphalt Shingle with min.Y2"plywood decking and 2"x 4" roof trusses <br /> 24"O.C. The roofing, decking,and roof trusses are in good condition.The existing structure will be <br /> adequate for supporting the additional PV dead load and wind loads. <br /> The securement method of the PV system is to be flush mounted to the asphalt shingle roof with the <br /> Ironridge railing and flash ings/attachments.The attachments can be attached up to 72"apart in <br /> roof zones 1 &2e,and 24"apart in roof zones 2n,2r,3e,&3r.The mounts should be staggered, <br /> where possible,to allow distribution of the design loads evenly to the structure.The mounts shall <br /> be installed with a min. 5/16"lag screw with minimum 2-5/16"thread length. <br /> Please see attached documents and contact me should you have any questions. <br /> Sincerely, <br /> D. Chad Godwin,PE 81360 <br /> Exp. 02/28/2021 ♦♦ E S D����i <br /> * N . 1360 <br /> A7E OF ' <br /> P '� � <br /> NAL <br />
The URL can be used to link to this page
Your browser does not support the video tag.