My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
21-1413
Zephyrhills
>
Building Department
>
Permits
>
2021
>
21-1413
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/9/2022 2:03:38 PM
Creation date
5/9/2022 7:20:07 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
21-1413
Building Department - Name
MUNOZ,ROSAIDY & SERRANO
Address
7808 BROAD POINTE DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
53
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Snow Load 0-20 psf <br /> Modules in Landscape <br /> Wind Speed Exposure 2:12<Roof Pitch<6:12 7:12<Roof Pitch<12:12 <br /> ASCE 7-05 ASCE 7-10 Cate o Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 <br /> B 159 93 59 <br /> 85 mph 110 mph C 114 67 42 88 88 <br /> D 96_ _ 56 35 91 74 74 <br /> B 146 _ 85 54 <br /> 90 mph 115 mph C 104 61 38 98 80 80 <br /> D 88 _ 51 32 83 68- 68 <br /> B 123 72 45 95 �95 <br /> 100 mph 125 mph C 88 51 32 83 68 68 <br /> D 74 "43 27 70 , 57 57 <br /> B----- ---98-� �-67 _ -'36`- --------93-- -----76---- —_76 <br /> 110 mph . 140 mph C 70 41 26 66 54 54 <br /> D 59 34 22 56 46 _ 46 <br /> B 85 50 31 81 66 66 <br /> 120 mph 150 mph C 61 36 22 58 47 47 <br /> D 51 30 19 49 40 40 . <br /> Notes: <br /> Spacing Governed by Snow Load <br /> 1:)Values in above table represent the maximum allowable spacing in inches for pullout forces only on EcoFasten Solar standoff, <br /> however the designer must round down to meet appropriate rafterspacing <br /> 2.)Maximum allowed spacing approved by EcoFasten Solar is 72" <br /> 3.)Maximum allowed standoff capcity=547#(per testing results) <br /> 4.)Includes additional factor of safety of 1.5 for lag pullout capacity <br /> 5.)Values based on a maximum module width of 40" <br /> 6.)Based on Risk Category II(ASCE 7-10)structures less than 30 feet in height <br /> 7.)All adjustment factors are set to 1.No site specific engineering is included in this table <br /> Snow Load 0-20 psf <br /> Wind Speed Exposure 2.12<Roof Pitch'<6:12 7:12<Roof Pitch<1.2:12 <br /> ASCE 7-05 ASCE 7-10 Category Zone 1 Zone 2 Zone 3 Zone 1. Zone 2 ,Zone 3 <br /> B 91 53 33 <br /> 85 mph 110 mph C 65 38 24 61 50 50 <br /> D 55 32 20 52 42 42 <br /> B 83 49 30 <br /> 90 mph 115 mph -C 59i 35 22. 56 46 46 <br /> D 50 29 18 47 38 �541 <br /> B 70 41 26 54 <br /> 100 mph 125 mph C 50 29 18 47 39 39 <br /> D 42 26 15 40 32 32 <br /> B 56 33 20 53 43 43 <br /> 110 mph 140 mph . C 40, 23 14 38 31 31 <br /> D 34, 19 12 32 26 26 <br /> B 49 28 18 46 37 37 <br /> 120 mph 150 mph C 35 20 12 33 27 27 <br /> D 29 17 10 28 22 22 <br /> Notes: <br /> -Spacing Governed by Snow Load <br /> 1.)Values in above table represent the maximum allowable spacing in inches for pullout forces only on EcoFasten Solar standoff <br /> 2.)Maximum allowed spacing approved by EcoFasten Solar is 48" <br /> 3.)Maximum allowed standoff capcity=547#(per testing results) <br /> 4.)Includes additional factor of safety of 1.5 for lag pullout capacity <br /> 5-)Values based on a maximum module length of 70" <br /> 6.)Based on Risk Category II(ASCE 7-10)structures less than 30 feet in height <br /> 7.)All adjustment factors are set to 1.No site specific engineering is included in this table <br /> www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.