Snow Load 51-60 psf ` <br /> Modules in Landscape <br /> Wind Speed Exposure 2:12<Roof Pitch<6:12 7:12<Roof Pitch<12:12 <br /> ASCE 7-05 ASCE 7-10' . CategoryZone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 <br /> B 5'• 5T5 5r5 3T 4 3' <br /> 85 mph 110 mph " C 55 55 42 34 34 4 <br /> D 5'5 55 35. 34 34 <br /> B 55 5 54 34 34 4 <br /> 90 mph 115 mph C 55 55 38 4 3 4 <br /> D 5 51 32 34 34 34 <br /> B 55 55 45 34 34 34 <br /> 100 mph 125 mph C 55 51 32 34 3 34 <br /> D 55 43 27 34 4 <br /> B 5• 55 36 34 34 <br /> 110 mph 140 mph C 55 41 26 4 34 4 <br /> D 55 34 22 4 34 <br /> - --- - - - ——— B --- 55 —-50— -- 31 3-4 4 34 <br /> 120 mph 150 mph C 55 36 22 34 34 <br /> D 51 30 1 19 34 3 3 <br /> Notes: <br /> ®Spacing Governed by Snow Load <br /> 1.)Values in above table represent the maximum allowable spacing in inches for pullout forces only on EcoFasten Solar standoff, <br /> however the designer must round down to meet appropriate rafterspacing <br /> 2.)Maximum allowed spacing approved by EcoFasten Solar is 72" <br /> 3.)Maximum allowed standoff capcity=547#(per testing results) <br /> 4.)Includes additional factor of safety of 1.5 for lag pullout capacity <br /> 5.)Values based on a maximum module width of 40" <br /> 6.)Based on Risk Category II(ASCE 7-10)structures less than 30 feet in height <br /> 7.)All adjustment factors are set to 1.No site specific engineering is included in this table <br /> Snow Load 51-60 psf <br /> Wind Speed Exposure 2:12<Roof Pitch<6:12 7:12<Roof Pitch<12:12 <br /> ASCE 7-05 ASCE 7-10 Category Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 <br /> 85 mph 110 mph C 24 <br /> D_ 32 20- <br /> B 30 <br /> 90 mph 115 mph C 22 <br /> D 29 18 <br /> B 26 <br /> 100 mph 125 mph C 29 18 <br /> D 26 15 <br /> 110 mph 140 mph C 23 14 <br /> D 19 _ 12 <br /> --- —'-- B--- — 28 18 <br /> 120 mph 150 mph C 20 12 <br /> D 29 17 10 <br /> Notes: <br /> ,-Spacing Governed by Snow Load <br /> 1.)Values in above table represent the maximum allowable spacing in inches for pullout forces only on EcoFasten Solar standoff <br /> 2.)Maximum allowed spacing approved by EcoFasten Solar is 48" <br /> 3.)Maximum allowed standoff capcity=547#(per testing results) <br /> 4.)Includes additional factor of safety of 1.5 for lag pullout capacity <br /> 5.)Values based on a maximum module length of 70" <br /> 6.)Based on Risk Category II(ASCE 7-10)structures less than 30 feet in height <br /> 7.)All adjustment factors are set to 1.No site specific engineering is included in this table <br /> www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 12 <br />