My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
21-1418
Zephyrhills
>
Building Department
>
Permits
>
2021
>
21-1418
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/9/2022 2:04:40 PM
Creation date
5/9/2022 7:24:01 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
21-1418
Building Department - Name
COLON,FRANCISCO & LYDIA
Address
36046 STABLE WILK AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DocuSign Envelope ID:7FBB976C-F93F4B2A-8632-2A5DFF93FCBB <br /> Wind Parameters <br /> Wind Speed 145 mph <br /> Exposure Category D <br /> Roof Angle, 0 23.0 deg <br /> Product Information <br /> No.of Panels 29 <br /> Weight 3.00 psf including mounting system <br /> Installed Area 526.4 ft2 <br /> No.of Connectors 38 <br /> Total Existing Roof Load=Roof Dead Load+(Roof Live Load or Snow)x Spacing <br /> 69.32 plf <br /> Total New Roof Load=Roof Dead Load+Added Dead Load+(Roof Live Load or Snow)x Spacing) <br /> 35.32 plf <br /> Change in Demand=(Total New Load-Existing Load)/Existing Load <br /> 49.05% <br /> Total New Gravity Loads are less than Existing Loads. OK <br /> 2015 IEBC Section 707.2 states: <br /> "Where addition or replacement of roofing or replacement of equipment results in additional dead loads,structural components supporting <br /> such reroofing or equipment shall comply with the gravity load requirements of the International Building Code. EXCEPTION 1.Structural <br /> elements where the additional dead load from the roofing or equipment does not increase the force in the element by more than 5 percent." <br /> 2015 IRC Section AJ501.4 states: <br /> "The minimum design loads for the structure shall be the loads applicable at the time the building was constructed,provided that a dangerous <br /> condition is not created. Structural elements that are uncovered during the course of the alteration and that are found to be unsound or <br /> dangerous shall be made to comply with the applicable requirements of this code." <br /> 2017 FBC Section AJ104.1 states: <br /> "Detached one-or two-family dwellings that are not irregular buildings under Section R301.2.2.2.5 and are not undergoing an extensive <br /> reconstruction shall not be required to be evaluated." <br /> Page 2 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.